9.23.2 Remove the Feed Screw
NOTE
Step 1 is different for EM1 / EM2 units and for EM3 / EM4 units. Refer to
the correct step 1 for your system. The remaining steps are the same for all
units.
EM1 / EM2 Units
1. Release the feed screw from the drive shaft.
a) With the drive power on, unscrew the collet securing the feed screw
to the feed drive shaft.
1
2
1. Feed screw
2. Collet (right hand
thread)
b) Push the feed screw, the collet and the retaining nut out of the feed
drive shaft toward the barrel.
1
3
2
1. Barrel
2. Collet
3. Retaining nut
c) Remove the retaining nut from the screw. The nut is left-hand thread.
1
2
1. Remove retaining nut
(left hand thread)
2. Remove collet
(right hand thread)
9-31
MAINTENANCE
E-Multi User Manual
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.