11.12 ER3 / ER4 Installation
WARNING
Do not place any body parts between the two mating parts. Serious injury
may result from having fingers or hands crushed between moving parts.
CAUTION
Do not tighten the clamping screw so much that the unit locks as this will
prevent proper alignment of the nozzle to the inlet.
CAUTION
1. Remove adapter plate from shipping crate.
2. Place the adapter plate on the stationary platen. Install the bolts
(M20X90) in a cross pattern and torque it to 339 Nm (250 ft-lbs).
11-18
E-Multi User Manual
E-MULTI RADIAL OPTION