For optimal performance and safety concerns, we HIGHLY RECOMMEND
that the Infrared Heating System be operated at a min. of 87'' ht. Or the
maximum extended length of the telescopic body sections.
Pull up on release levers of tightening clamps and adjust tension using the black knobs.
Raise and lower the telescopic sections and/or swivel to desired position and then push
in clamp levers to secure. Do NOT over tighten tension knobs. There should only be a
moderate amount of tension to maintain the telescopic position of your heater.
To Adjust The IR Telescopic Body:
Note: Be sure to adjust the slack as needed on the electrical
cord when raising or lowering telescopic body.
The infrared electric heating system comes equipped with a heavy duty.
16/3 gauge wire and grounded plug. This appliance must be used with an outlet that has been installed
and grounded in accordance with all local codes and ordinances. Make sure that the heater is
connected to an outlet having the same configuration as the plug shown in
Fig.8
Do NOT use
an adapter with this product. Check with a licensed electrician if the grounding instructions are
not understood completely or if the wall outlet does not match the plug.
Step 2
Your infrared electric heating system is ready to enjoy. Plug the appliance in and beginning enjoying the warmth!
Step 3
Always UNPLUG unit when not in use!
This appliance MUST be grounded.
* When using outdoors, we recommend using a certified GFI (Ground Fault
Interrupt) outlet to protect against electrical shock.
* All installation must be in accordance with I.E.E. safety regulations or
equivalent.
* Avoid the use of an extension cord with this appliance, if one is used,
it MUST be at least a 14/3 wire, grounded cord, 50 ft max. length.
* Do not place any objects such as furniture, papers, clothing or curtains
closer than 3 ft to the front and the sides of the heater.
* ALWAYS unplug the IR heater unit when not in use.
Before turning on your Infrared Heating System, extend all 3 telescopic
sections to their maximum extended length. Release clamp levers and
pull up on each of the sectional steel tubes until each tube stops. Then
push in clamp levers to secure sections in place. Adjust the tension
knobs as needed to maintain height position.
Step 1
Place the infrared heater on FLAT, LEVEL surface only.
Move and position the electrical cord so it is not a trip hazard and not
exposed to water or moisture.
Refer to coverage area in
Fig. 7
for best positioning location.
Safety Tilt Switch Mechanism: This unit has a built in shut off system. Power
will shut off automatically should the unit be accidentally knocked over or
tilted past 15 degrees .To reset, unplug unit from wall outlet, reposition on
flat level surface and plug in again.
The instruction manual of grounded heaters shall include the following or
equivalent wording: (In the case of a heater rated for a nominal 120 voilts.)
This heater is for use on 120 voits.The cord has a plug as shown at Ain
Fig.8. An adapter as shown at C is available for connecting three-blade
grounding-typeplugs to two-slot receptacles.The grounding lug
extending from the adapter must be connected to a permanent ground such
as a properly grounded outlet box.The adapter should not be used if a three-
slot grounded receptacle is available.
Grounding instructions
Creates a
generous zone
of comfort!
19 ft
10.5 ft
10 ft
87"ft
45d egrees
Angle of
Heat spread
Fig.7