DC READY
®
, MOIXA
®
are registered trademarks, logos, illustrations are property of
Moixa Energy Holdings Ltd. Registered in England and Wales. © Moixa Technology Ltd 2016.
www.moixa.com
Moixa Technology Ltd,
One Fellmongers Path,
London SE1 3LY
30 |
5.
Remove the replacement unit from packaging and hang on the screws, replace
the screw holding the base, wire the replacement unit to the rotary isolator and
replace cover.
6.
If a DC circuit or DC solar panels are present then care must be taken to note
the position of all cables, and to ensure that these are reproduced on the re
-
placement unit
7.
Care must be taken to ensure that the clamp meters are replaced in the right
sockets and sending correct readings. See install manual and clamp trouble
shooting 03E.08
8.
Put the battery modules onto the Moixa unit, switch on the unit.
9.
Check that the unit is online and reliably sending data. Ring Moixa technical
team, report that work is complete and request that they login to the unit to
check that it is working correctly.
10.
Press submit on the Moixa app to send details of the job to the Moixa team.
6.
7.
6.
swap
battery
unit
for
replacement