MoistAir MA0600 Скачать руководство пользователя страница 7

 

 

 

10 

 

Filter Replacement and Care  

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 

WARNING:

 

To reduce the risk of 

shock or injury from moving parts, 
always unplug humidifier before 
removing or replacing any parts. 

CAUTION:

 

To help retard bacteria 

growth and keep maximum 
efficiency, the filter should be 
replaced at least once per season, 
or more often under hard water 
conditions. Use MAF2 replacement 
filter. 

Replace the evaporative wicking filter 
at least once per humidification season 
or more depending on water conditions 
in your area. 

 

Filter Replacement 

1. Unplug humidifier. Before removing 
the filter, move the humidifier to an 
area not susceptible to water damage. 
(i.e. kitchen or bath areas). 

2. Remove the water bottle and set 
aside. Be sure not to bump or damage 
the fill valve. 

3. The upper housing and the base are 
held together by two hooks at the front 
of the housing and a flexible snap in 
the rear. To remove the housing, press 
in on the triangular shaped snap at the 
rear of the humidifier, below the cord 
exit, while lifting upward, tilting the 
upper housing forward to clear the 
hooks at the front of the base. 

4. Set the upper housing aside.  
The filter is now accessible. 

5. Take note of the filter position. 
Remove the filter. You may want 
to clean the base at this time. See 
the “Cleaning and Maintenance” 
section of this manual. 

6. Install a new filter (MAF2) into 
the base. Position the filter 
between the uprights in the bottom 
of the base. The filter should be 
resting on the floor of the base. 

7. Return the upper housing to the 
base by first placing the hooks 
located near the front of the base 
into the mating holes in the upper 
housing. Then tilt the upper 
housing down towards the base 
until the rear snap engages the 
main housing. 

8. Reposition the humidifier to its 
operating position. 

9. The humidifier is now ready to 
be filled for operation. 

 

 

 

   Recommended 

 

When Outdoor  

Indoor  Relative  

Temperature is: 

   Humidity is: 

  -10˚F -24˚C 

  20% 

     2˚F -18˚C 

  25% 

   10˚F -12˚C 

  30% 

> 20˚F    -6˚C 

  35% 

Step 4. Setting the Controls 

Where you set your desired 
humidity levels depends on 
your personal comfort level, 
outside temperature and 
inside temperature. A 
starting Set point of 30%-
40% ROOM humidity is 
recommended but there may 
be conditions that require a 
different setting.  

The chart provided offers general guidelines for selecting indoor humidity. 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

IMPORTANT:

 Water damage may result if condensation starts to form 

on windows or walls. Humidity SET point should be lowered until 
condensation no longer forms. We recommend room humidity levels 
do not exceed 50%. 

Operating the Controls 

Digital Display 

Press the power button once to turn  
the unit on

*

 

. Initially there is a slight 

delay while the electronics calibrate. 
 Two bars (--) appear during this time.  

Once calibration is complete a ROOM 
humidity reading between 20% – 95%  
will be displayed. A flashing 20 display 
indicates that the room humidity is less 
than 20%. 

NOTE

: The default settings at initial  

startup are 

(LOW)

 F1 fan speed and 

65% SET

 humidity. After desired settings 

are selected by the user, they remain as 
long as the unit remains plugged in and 
there is no power interruption. If the unit 
is unplugged the 

original

 default settings 

will be restored. 

*

Humidifier fan should operate at 

initial startup. If it does not, refer 
to “Fan not operating (digital 
display is illuminated)” in the 
“Troubleshooting” section on 
page 13 of this manual.

 

Содержание MA0600

Страница 1: ...ide TOWER HUMIDIFIER 6 Gallon Output with Digital Readout Model MA0600 CAUTION Before using this product read this manual and follow all its Safety Rules and Operating Instructions Safety Assembly Operation Maintenance Parts Essick Air Products 5800 Murray St Little Rock AR 72209 www moistair com Part No 1B71754 Printed in China 04 08 ...

Страница 2: ...warranted for two years This warranty does not apply to filters or wicks which are customer replaceable parts This warranty applies only to the original purchaser of the product when it is purchased from a reputable retailer dealer This warranty does not apply to damage from accident misuse alterations unauthorized repairs unauthorized use mishandling unreasonable use abuse including failure to pe...

Страница 3: ...Manual not shown Stock item May be secured through the Hardware Department of most retail stores 3 KNOW YOUR HUMIDIFIER Description MA0600 Gallon Output 24 hrs Capacity of Bottle Capacity of Base Sq Ft Coverage Fans Speeds Replacement Filter Auto Humidistat Auto Shut Off Controls UL CUL Listed Volts Hertz Amps High Speed Watts High Speed 6 gallons 1 25 gallons 1 25 gallons 1300 3 MAF2 Yes Yes Elec...

Страница 4: ...t operating digital display is illuminated ROOM humidity level is not 3 or more below SET humidity level Reservoir is empty Raise SET humidity level if desired Increase fan speed Fill humidifier with water Fan running continuously SET humidity level is 65 ROOM humidity level has not reached 1 or more above SET humidity level A Set humidity percentage of 65 operates fan continuously Adjust SET leve...

Страница 5: ...The humidifier should be positioned with the back cord exit side and sides at least 2 inches away from the wall Air needs to enter through all of the louvers in the housing assembly in order for the humidifier to operate at peak efficiency NOTE Be sure humidistat located approximately 4 inches outside humidifier body on power cord is free from obstruction and away from any hot air register WARNING...

Страница 6: ...w filled to capacity For less frequent filling let the humidifier exhaust both the water from the bottle and the base before filling 11 Cleaning and Maintenance WARNING To reduce the risk of injury fire or damage to humidifier use only cleaners specifically recommended for humidifiers Never use flammable combustible or poisonous materials to clean your humidifier To reduce the risk of scalds and d...

Страница 7: ...to the mating holes in the upper housing Then tilt the upper housing down towards the base until the rear snap engages the main housing 8 Reposition the humidifier to its operating position 9 The humidifier is now ready to be filled for operation 7 Recommended When Outdoor Indoor Relative Temperature is Humidity is 10 F 24 C 20 2 F 18 C 25 10 F 12 C 30 20 F 6 C 35 Step 4 Setting the Controls Where...

Страница 8: ...room humidity reading and F FILL indicating that additional water is required Also at this time the unit will automatically switch into DRY OUT MODE and continue to run on the lowest speed until the filter is dry 9 NOTE During this time the room humidity level will continue to be monitored and the humidifier will cycle the fan on and off until the filter is completely dry The fan will shut off lea...

Отзывы: