Installation
System extensions
Interior system connectors
System connectors (SV) are required to connect two system convector troughs or con-
vector parts to each other. The connection is performed in the inside as a standard. If
inside connection is impossible, it is also possible from the outside. System convector
parts with mitre fit are delivered ready-to-plug-in; they are also connected to each
other with system connectors. The number of system connectors depends on the
system convector height:
System convector height
Number of system connectors
91 mm
1 set
111 mm
1 set
141 mm
2 sets
191 mm
2 sets
¾
Push the connectors in even distances into the grooves of the convector trough.
¾
Pull together the convector troughs so that they flush.
¾
Fix the connection by means of stud screws M6 and an Allen key of size 3.
Exterior system connectors
4
5
Exterior adjustment block with fixing
Exterior adjustment block with foot
5
4
1
2
3
Interior adjustment block: Height adjustment
Levelling
Exterior adjustment block: Height adjustment
Levelling
Levelling is the same for interior as well as for exterior adjustment blocks. An Allen
key (4 mm) is required for the height adjustment of the adjustment blocks.
¾
Adjust the individuals adjustment blocks in the required direction.
¾
Adjust the height of the individual adjustment blocks until the device is com-
pletely aligned.
¾
Check the alignment.
1
2
3
6
6
Interior adjustment block
Aligning the system convector
Содержание WLK 180
Страница 19: ...19 ENG DEU RUS ITA DAN Notizen ...
Страница 39: ...39 ENG DEU RUS ITA DAN Notes ...
Страница 59: ...RUS ENG DEU ITA DAN 59 Заметки ...
Страница 79: ...79 ITA ENG RUS DEU DAN NOTE ...
Страница 81: ...DAN ENG RUS ITA DEU MANUAL Systemkonvektor WLK 180 WLK 260 WLK 320 WLK 410 WLKP 180 WLKP 260 WLKP 320 WLKP 410 ...
Страница 99: ...99 DAN ENG RUS ITA DEU Notater ...