![MOGAS ISOLATOR 2.0 Скачать руководство пользователя страница 34](http://html.mh-extra.com/html/mogas/isolator-2-0/isolator-2-0_installation-operation-and-maintenance-manual_1823357034.webp)
ESI-6149 © Copyright 01/22/2018 MOGAS Industries, Inc.
www.mogas.com
34
100 PSI
75 PSI
PRESSURE END
Stem turns 90° counter-clockwise to
open
.
This information is indicated on flange in this location .
Pressure End
— When valve is in closed position,
highest pressure should be on this side .
Each valve will come with an ‘M’ number stenciled
on the body of the valve, which should be referred
against the “How to Order” section of the ISOLATOR
2 .0 brochure . ‘M’ number is essentially the model
number that can be used to decipher the valve
configuration including size, pressure class, inlet/
outlet connection, body material, ball and seat trim,
coating, stem material, maximum temperature and
operator as seen below:
Additional information may also be provided on
identification tags per customer request .
IS100
01
F
F
SS
1
1
1
65
1
example: 1 inch, ASME 150 Class, RFF inlet, RFF outlet, A182-F316 body, 316SS trim, Chrome Carbide coating, 17-4 stem, 650° F, bare stem =
IS100-01FFSS111651
Bore Size,
Inlet × Outlet (in)
Pressure
Class
Connection
Body
Material
Ball/Seat
Trim
Coating
Stem
Material
Maximum
Temp.
1
Operator
Inlet Outlet
Locate Valve Information
STEM ORIENTATION
Viewed from TOP