background image

7.0 Cable Gland

The X450 and LED450 beacons are supplied as standard with 1 x M20 threaded side cable entry with 

provision for up to 4 supplied to special order.

SAFETY WARNING

If the X450 and LED450 are used at high ambient temperatures, ie over +40

0

C then the cable entry 

temperature may 70

0

C and therefore suitable heat resisting cable glands must be used, with a rated 

service temperature of at least 95

0

C.

If a high IP (Ingress Protection) rating is required, a suitable sealing washer must be fitted under the cable 

gland.  When only one cable entry is used, the other one must be closed with a blanking plug, which must 

be suitably approved for the installation requirements.

8.0 End of Line Monitoring

An end of line monitoring diode or an end of line monitoring resistor can be connected across the 24v+ and 

0 terminals. If an end of line monitoring resistor is required, this must be specified by the customer.

9.0 Maintenance

During the working life of the product, little or no maintenance  is required due to the robust maintenance-free 

surface.  Composite material of PC (Polycarbonate) is abrasion and corrosion resistant therefore the 

products are able to be used in both indoor and outdoor industrial conditions/under harsh environments.   

It can also be applied in areas with high impact loads without additional protective constructions due 

to very good mechanical properties. 

If abnormal or unusual environmental conditions occur due to accident etc, visual inspection is 

recommended. To avoid electrostatic charge build-up, only the exterior of the product can be cleaned 

with a damp cloth. If spare parts are required, these can be supplied by Moflash. If any failure occurs but 

not caused by human factor, the product can be returned to Moflash for free repair or replacement during

 

warranty period.

CAUTION: 

Not suitable to be used under circumstance which exposed or near to the source or concentrated acids, 

aromatic hydrocarbons, halogens and ketones.

10.0 Conditions for Safety Use

i)   This apparatus is suitable to be used only in ambient temperature as stated below:

ii)   Other  than  by  the  product  manufacturer,  painting  and  surface  finishing  are  not  permitted  by  the

 

 

third party.

iii)  When used in dusty atmosphere, cable entry devices or stopping plugs have to be selected and installed  

 

carefully in order to maintain the IP rating (IP66) of the product.

 

 

 

 

 

               Moflash part code S00583 - Issue 2

INSTALLATION & 

TECHNICAL INFORMATION 

PLEASE READ PRIOR TO INSTALLATION 

X450 & LED450 Series

Industrial Xenon & LED Beacons

VISUAL SIGNALLING DEVICES

Website: www.moflash.com        Email: [email protected]

Type

Ambient Temp

X450 and LED450

-40

0

C to +70

0

C

APPROVALS

 

AND

CONFORMITIES