3
4.0 Zones, Gas Groups and Temperature Classifications
The Moflash Intrinsically Safe Sounder-Beacon Range is certified to the
following:
Ex ia IIC T5 Ga, Ex ia IIIC T100C Da, Ex ia I Ma.
This means that the units can be installed in locations with the following condi-
tions when connected to an approved system:
Zones
Zone 0
Explosive gas air mixture continuously present.
Zone 1
Explosive gas air mixture likely to occur in normal operation.
Zone 2
Explosive gas air mixture not likely to occur, and if it does, it will
only exist for a short time.
Zone 20
Explosive dust air mixture is continuously present.
Zone 21
Explosive dust air mixture likely to occur in normal operation.
Zone 22
Explosive dust air mixture not likely to occur, and if it does, it
will only exist for a short time.
Gas Groupings
IIA Propane Group, IIB Ethylene Group and IIC Hydrogen and Acetylene
M1 Methane, Carbon Dust
Equipment Category
1GD & M1 Temperature Range: -40°C < Ta <55°C
Dust
IIIA Fibres and Flying, IIIB Flour and Grain, IIIC Coal Dust and Metal Dust.
The maximum surface temperature of operating product in the Sounder will not
exceed 100°C.
A Declaration of Conformity and also the Sounder Range ATEX and IECEX
Certificates are available on request or alternately visit
www.Moflash.co.uk
.