4.0 Zones, Gas Groups and Temperature Classifications

The Moflash Intrinsically Safe Sounder-Beacon Range is certified to the 

following:

Ex ia IIC T5 Ga, Ex ia IIIC T100C Da, Ex ia I Ma. 

This means that the units can be installed in locations with the following condi-

tions when connected to an approved system:

Zones

Zone 0   

Explosive gas air mixture continuously present.

Zone 1    

Explosive gas air mixture likely to occur in normal operation. 

Zone 2   

Explosive gas air mixture not likely to occur, and if it does, it will  

 

only exist for a short time. 

Zone 20  

Explosive dust air mixture is continuously present.

Zone 21  

Explosive dust air mixture likely to occur in normal operation. 

Zone 22  

Explosive dust air mixture not likely to occur, and if it does, it  

 

will only exist for a short time. 

Gas Groupings 

IIA Propane Group, IIB Ethylene Group and IIC Hydrogen and Acetylene 

M1 Methane, Carbon Dust

Equipment Category

1GD & M1 Temperature Range: -40°C < Ta <55°C

Dust

IIIA Fibres and Flying, IIIB Flour and Grain, IIIC Coal Dust and Metal Dust.

The maximum surface temperature of operating product in the Sounder will not 

exceed 100°C.

A Declaration of Conformity and also the Sounder Range ATEX and IECEX  

Certificates are available on request or alternately visit 

www.Moflash.co.uk

.

Содержание IS-SB-02 Series

Страница 1: ...N PLEASE READ PRIOR TO INSTALLATION Website www moflash com Email technical moflash co uk Moflash Intrinsically Safe Sounder Beacon Range S00605 Issue 7 28 07 2020 VISUAL AND OR AUDIBLE SIGNALLING DEV...

Страница 2: ...stant 33mA The Sounder has diode reverse polatiry protection and is also End of Line resistor compatible 2 0 Intrinsically Safe Labelling The product will have an individual serial number printed onto...

Страница 3: ...a short time Zone 20 Explosive dust air mixture is continuously present Zone 21 Explosive dust air mixture likely to occur in normal operation Zone 22 Explosive dust air mixture not likely to occur a...

Страница 4: ...tic shown in Fig 1 with side cutters or similar tool To open a locked head remove the small rubber bung from the hole on the side of the head unit insert a tool into the hole and depress the clip whil...

Страница 5: ...it comes free Remove the appropriate fixing hole and conduit knockouts from the back box The back box provides IP66 protection For this to be maintained suit ably rated minimum IP66 M20 cable glands m...

Страница 6: ...led base the alarm tone and light output must be set see page 5 To activate both Sounder and Beacon together the negative supplies need to be connected together via a wire link not supplied in the bas...

Страница 7: ...s done by switching the negative connections as shown in the table on page 6 There are a number of ways for this to be accomplished through the suitable barriers a number of methods are shown below Fo...

Страница 8: ...stallation sheet The combined unit can be turned on and off either by using a suitably placed switch in the positive or negative rails switch must be of suitable ratings if installed in the Hazardous...

Страница 9: ...er which can allow reverse polarity monitoring to take place and a fire panel compatible with Intrinsically Safe products must also be used If required an external switch can be wired in series with t...

Страница 10: ...been sustained during its normal operation The enclosure is non conducting and may generate an ignition capable level of electrostatic charge under certain extreme conditions It is the responsibility...

Страница 11: ...these units up without the correctly rated barrier could damage these products and so void any protection ratings Specific Conditions of Use 1 Clean equipment regularly to prevent dust build up with a...

Страница 12: ...89 14 400Hz O I I O I O 92 15 550Hz 0 7s 1000Hz 0 33s O I I I O O 93 16 1500Hz 2700Hz 3Hz O I I I I O 98 17 750Hz I O O O O O 93 18 2400Hz I O O O I O 105 19 660Hz I O O I O O 93 20 660Hz 1 8s ON 1 8...

Отзывы: