22
CONVERSION OF GAS
Your cooker is designed to work with natural
gas, propane or butane. It is not designed
for butane or propane air.
The LPG conversion kit is available from
your Service Force Centre and must be
fitted by a Corgi Registered engineer.
For changing the gas type it is necessary to:
•
replace the nozzles (hob, oven and
grill);
•
adjust the minimum level (hob and
oven);
•
adjust the primary air (oven and grill);
•
check the gas connection.
Stick the label supplied with the
appliance (in the nozzles bag)
corresponding to the gas type utilised.
Replace the nozzles of the hob burners
Every appliance has spare nozzles for every
type of gas. The whole length of every
nozzle is marked in millimetres on the
nozzle.
Hob burners
•
Remove the pan support;
•
Remove the caps and the burner
crowns;
•
Using a No 7 socket spanner unscrew
the nozzles and replace them with those
required for the type of gas in use (see
table no. 1).
Reassemble the parts following the same
procedure in reverse.
These burners do not need any primary air
regulation.
Adjustment of minimum level for the hob
burners
The burner is correctly adjusted when the
flame is stable silent and goes out without
any noise.
When changing the type of gas check that
the minimum level is correct. The air
admission is correct when the flame is
about 4 mm in length.
The top burners do not need adjustment of
primary air.
Check that, turning the knob quickly from
the maximum position to the minimum one,
the flame does not go out.