Moffat TV337 Скачать руководство пользователя страница 5

BEFORE YOU BEGIN

5

Installation

Range Hood

Instructions

Read these instructions completely and carefully.

IMPORTANT –

Save these

instructions for local inspector’s use.

IMPORTANT –

Observe all

governing codes and ordinances.

Note to Installer –

Be sure to leave these

instructions with the Consumer.

Note to Consumer –

Keep these instructions

for future reference.

Skill level

– Installation of this appliance requires

basic mechanical and electrical skills.

Completion time

– 30 minutes–3 hours

Proper installation is the responsibility of the

installer.

Product failure due to improper installation is not

covered under the Warranty.

NOTE: Read the ductwork sections only if you do not
have existing ductwork. If you have existing ductwork,
skip to the “Damage” section and proceed.

The venting system must exhaust to the outside.

This hood can be vented vertically through upper
cabinets or horizontally through an outside wall.
Ductwork is not included.

Exhaust connection: 

The hood exhaust has been designed to mate with
standard 3¼” x 10” rectangular ducting or 7” diameter
round ducting.
If a 6” round duct is required, a rectangular-to-round
transition adaptor must be used*. 

Do not use less than 

a 6

diameter duct.

Maximum duct length: 

For satisfactory air movement, the total duct length 
of a 3¼” x 10” rectangular, 6” or 7” diameter round 
duct

should not exceed 65 equivalent feet. See the

WORKSHEET–CALCULATE TOTAL EQUIVALENT
DUCTWORK LENGTH section.

NOTE:

It is important that ducting be installed using 

the most direct route and with as few elbows as possible. 
This ensures clear venting of exhaust and helps prevent
blockages.

Also, make sure dampers swing freely and

nothing is blocking the ducts.

Elbows, transitions, wall and roofcaps, etc.,

present additional resistance to airflow and are
equivalent to a section of straight duct longer than their
actual physical size. When calculating the total duct
length, add the equivalent lengths of all transitions and
adaptors plus the length of all straight duct sections. The
charts on the following pages show you how to calculate
total equivalent ductwork length using the approximate
feet of equivalent length of some typical ducts.

* IMPORTANT:

If a rectangular-to-

round transition adaptor is used, the
bottom corners of the damper will
have to be cut to fit, using the tin
snips, in order to allow free
movement of the damper. 
Equivalent lengths of duct pieces 
are based on actual tests and reflect
requirements for good venting
performance with any hood.

DUCTWORK REQUIREMENTS**

WARNING –

Before beginning the

installation, switch power off at service panel and lock
the service disconnecting means to prevent power
from being switched on accidentally. When the service
disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, 
to the service panel.

FOR YOUR SAFETY:

Questions?

Call 1-800-561-3344 

or Visit our Website at: 

www.moffatappliances.ca

An optional Power Cord Connection Kit, model
JXHC1, is available at extra cost from your GE
supplier for installation using a standard 3-prong,
grounded wall outlet. Follow the Installation
Instructions packed with the kit to connect 
the power cord to the range hood.

OPTIONAL POWER CORD KIT JXHC1

** 1 Ft = 0.3 m

1” = 2.5 cm

Содержание TV337

Страница 1: ...Hood Light 4 Hood Surfaces 4 Controls 3 Installation Instructions 5 13 Consumer Support Consumer Support Back Cover Warranty 14 TV337 Vent options only Owner s Manual and Installation Instructions Wr...

Страница 2: ...her and you already know how to operate it 2 The fire is small and contained in the area where it started 3 The fire department is being called 4 You can fight the fire with your back to an exit Based...

Страница 3: ...Instructions 3 Using the hood controls Throughout this manual features and appearance may vary from your model FAN Control Turn to HI MED or LO as needed Continuous use of the fan system while cooking...

Страница 4: ...ver into the top opening Gently push the cover up and press the sides to fit the side prongs into the side openings Release and the cover will lock in position Hood Light The charcoal filter cannot be...

Страница 5: ...with as few elbows as possible This ensures clear venting of exhaust and helps prevent blockages Also make sure dampers swing freely and nothing is blocking the ducts Elbows transitions wall and roofc...

Страница 6: ...IVALENT NUMBER PIECES LENGTH x USED TOTAL 6 Round 24 Ft x Ft wall cap 18 ft w o with damper x Ft damper 6 Round 33 Ft x Ft roof cap 6 Round 2 Ft x Ft to 3 x 10 rect transition 6 Round 4 Ft x Ft to 3 x...

Страница 7: ...mer repair or replacement must be made by arrangement between customer and installer DAMAGE SHIPMENT INSTALLATION PARTS INCLUDED MOUNTING SPACE NOTES This range hood is for installation over ranges or...

Страница 8: ...CHOOSE VENT OPTION Determine the vent option that your installation will require and that is available for your model from the below choices 1 IMPORTANT If the hood is to be installed in a recirculati...

Страница 9: ...Strain relief clamp 2 3 4 5 Metal grease filter Installation Instructions Back knockout Top knockout Strain relief clamp 1 2 5 cm FOR 3 X 10 RECTANGULAR DUCTED DISCHARGE INSTALLATIONS ONLY Attach exha...

Страница 10: ...Wood shims recessed bottom cabinets only shims must be a minimum of 3 8 thick and cut to fit the width of the inner recessed cabinet bottom Vertical duct access hole 95 8 13 8 1 7 3 A Outside top exh...

Страница 11: ...d the front of the cabinet so you can move the duct freely when installing the hood It may also ease installation by cutting the hole 10 instead of 10 10 1 Ft 0 3 m 1 2 5 cm SCREW IN PARTWAY Drive a m...

Страница 12: ...ete the electrical wiring according to National Electrical Code and local codes NOTE This hood must be permanently grounded Connect house wiring 120 VAC to hood wiring 18 INSTALL LIGHT BULB NOTE A lig...

Страница 13: ...e Reinstall and adjust as needed The fan does not work but the lights do Switch power off at the service panel and lock the service disconnecting means to prevent power from being switched on accident...

Страница 14: ...within Canada If the product is located in an area where service by a Mabe Authorized Servicer is not available you may be responsible for a trip charge or you may be required to bring the product to...

Страница 15: ...www moffatappliances ca Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes VISA MasterCard and Discover cards are accepted Order on line...

Отзывы: