-26-
Revision 2/F3506
Two Screws
6.3.11 WATER SOLENOID
6.3.9 HOLD THERMOSTAT
1) Open control panel (refer 6.2.1) and undo
two screws securing hold thermostat
bracket.
2) Transfer wires to new thermostat.
3) Remove service panel (refer 6.2.2) and
from inside of oven loosen the thermostat
phial bracket.
4)
Withdraw old thermostat phial through
rear of oven.
5) Insert new thermostat.
6) Re-assemble in reverse order.
Two
Screws
Figure 6.3.13
1) Ensure water supply is turned off.
2) Inside the oven remove the baffle (refer
6.2.3), then unscrew the water injection
nozzle.
3)
With the service panel removed (refer
6.2.2) remove the wires from the solenoid.
4) Disconnect hose fitting.
5)
Unscrew the three screws holding
solenoid bracket to the rear of unit and
remove valve assembly.
Figure 6.3.15
Figure 6.3.16
Figure 6.3.12
Water Injection
Nozzle
Three Screws
6) On suitable work surface, remove brass
piping connections (1/2” spanner) and two
screws (on bracket) and extract solenoid.
7) Secure new solenoid with screws, and
re-assemble. Check that flow direction as
marked on valve is correct (flow into spray
nozzle).
Brass
Connections
Two
Screws
6.3.10 MINI-CONTACTOR
1)
Open control panel (refer 6.2.1) and
transfer wires from old mini-contactor to
new contactor.
2) Remove two screws securing old mini-
contactor to control panel.
Figure 6.3.14
3)
Secure new mini-contactor to control
panel using two screws.
Two Screws
Figure 6.3.17
Содержание turbofan E31
Страница 4: ...4 Revision 2 F3506...
Страница 32: ...32 Revision 2 F3506 7 ELECTRICAL CIRCUIT SCHEMATIC...
Страница 33: ...33 Revision 2 F3506 8 ELECTRICAL WIRING DIAGRAM...
Страница 36: ...36 Revision 2 F3506 11 PARTS DIAGRAMS 11 1 MAIN ASSEMBLY...
Страница 39: ...39 Revision 2 F3506 11 2 CONTROL PANEL ASSEMBLY...