11

Fault Finding

Preliminary Electrical Systems
Check

A. EARTH CONTINUITY CHECK

 - Appliance must

be electrically disconnected - meter set on 

(Ohms) x 1 scale and adjust zero if necessary.

a) Test leads from any appliance earth point to earth

pin on plug. Resistance should be less than
0.1 

Ω 

(Ohm), check all earth wires for continuity

and all contacts are clean and tight.

B. INSULATION CHECK

 - Appliance electrically

disconnected, all switches ON.

a) meter set on 

 (Ohms) x 1 scale.

Test leads from L to N in appliance terminal
block. If meter reads «0» then there is a short
circuit.

b) meter set on 

 (Ohm) x 100 scale.

Repeat test with leads from L to E. If meter reads
less than 

 (infinity) there is a fault.

NOTE - Should it be found that the fuse has failed
but no fault is indicated - a detailed continuity check
(i.e. by disconnecting and checking each
component) is required to trace the faulty
component.

It is possible that a fault could occur as a result of
local burning/arcing but no fault could be found under
test. However a detailed visual inspection should
reveal evidence of burning around the fault.

START

Isolate appliance
and carry out:

A:

 Earth Continuity

check.

 Has inlet fuse blown?

Carry out:

C:

 Polarity check.

Electricity supply
should now be
satisfactory.

Carry out:

D:

 Resistance to

Earth check.

Inlet wiring
faulty.
Rectify any
fault.

Isolate appliance and
carry out:

B:

 Insulation check.

Rectify any fault
including replacing
fuses as necessary.

SOCKET

(face view)

PLUG (with cover
removed)

Earth Wire
Green/Yellow

Neutral Wire
Blue

Brown

Blue

Green
Yellow

Green
Yellow

Brown

Blue

(   )

FUSE

(   )

E

N

L

NO

YES

NO

YES

1. IGNITOR SWITCHES

2. IGNITOR UNIT

Wiring Diagram

2

1

N

L

N

1
2
3
4
5
6

L

N

Содержание MGH 701

Страница 1: ...GAS HOB MGH 701 Please read this instruction booklet before using the appliance GB...

Страница 2: ...on should be improved by opening a window or increasing the extractor speed z Do not use this hob if it is in contact with water Do not operate the hob with wet hands z Ensure the control knobs are in...

Страница 3: ...2 Description of the Hob 3 Operation 4 Maintenance and Cleaning 4 Something Not Working 5 Service and Spare Parts 14 Guarantee Conditions 14 European Guarantee 14 Instructions for the Installer 6 Impo...

Страница 4: ...e or cleaning can be carried out you must DISCONNECT the hob from the electricity supply The hob is best cleaned whilst it is still warm as spillage can be removed more easily than if it is left to co...

Страница 5: ...l does not operate correctly contact your local Service Force Centre Please note that it will be necessary to provide proof of purchase for any in guarantee service calls In guarantee customers should...

Страница 6: ...eat Input 2 8 kW Natural Gas 10239 BTU HR 2 8 kW L P G 9556 BTU HR Front Left Burner auxiliary Heat Input 1 0 kW 3413 BTU HR Rear Right Burner semi rapid Heat Input 2 0 kW 6824 BTU HR Front Right Burn...

Страница 7: ...ea of 50 cm2 is required while if the volume exceeds 11 m3 no air vent is required However if the room has a door which opens directly to the outside no air vent is required even if the volume is betw...

Страница 8: ...e G 1 2 threaded elbow adjustment is fixed so that the washer is fitted between the components as shown in the diagram Screw the parts together without using excessive force Gas Connection Connection...

Страница 9: ...hob a should be easily removable to allow easy access if technical assistance is needed The space behind the kitchen unit b can be used for connections ON OFF SWITCH FLEX OUTLET ON OFF SWITCH FLEX OUT...

Страница 10: ...letter E or the earth symbol or coloured green and yellow Connect the blue neutral wire to the terminal in the plug which is marked with the letter N or coloured black Connect the brown live wire to...

Страница 11: ...ailed but no fault is indicated a detailed continuity check i e by disconnecting and checking each component is required to trace the faulty component It is possible that a fault could occur as a resu...

Страница 12: ...ght burner manually Check gas supply at burner Check continuity from N on the mains connector block and N on the ignitor unit Check continuity from L on the mains connector block and the taps ignition...

Страница 13: ...other burner The pressure reading should be nominally 20 mbar and must be between 17 mbar and 25 mbar Turn off the burner supplies Minimum adjustment screw Conversion from Natural Gas to LPG IMPORTANT...

Страница 14: ...commercial or similar environment plus those which are the subject to rental agreements Products of Moffat manufacture which are not marketed by Moffat EuropeanGuarantee This appliance is guaranteed...

Страница 15: ...15...

Страница 16: ...35689 8802 07 06 Grafiche MDM Forl www electrolux com...

Отзывы: