Electrical supply cable type CEN LEC H07 RN-F must
be installed using a suitable isolating switch which has
a minimum contact separation of 3mm in all poles.
Units that are part of a counter are pre wired in the factory
for connection on site, these counters depending on
the customers specification may be fitted with either an
isolator or MCB unit. In accordance with health and safety
at work acts, BS codes of practice, IEE regulations, building
standards, fire precautions act, and local authority and
building regulatiowwns etc. all appliances/units over 3Kw
require a qualified electrician to install them.
Do not connect to a different power supply from
stated on the data badge. This could damage
the unit. If you are in any doubt about the
correct supplies, contact a qualified electrician.