4: Installation conditions model HH1C
To ensure the satisfactory operation and optimum efficiency of this
unit, it is imperative that the ambient room conditions where the units
are being used do not exceed a room temperature of 25°c or exceed
a relative room humidity of 60%.
Should conditions exceed the above, the display units may not maintain
food temperatures at the required levels.
E & R Moffat cannot accept responsibility for the performance of the
units being used in extreme conditions.
Do not install units where there is high radiated heat,e.g. direct sunlight,
room heaters, or bright spot lights. Do not install units in draughty
conditions where the air movement is greater than 0.2mtr/sec.
(e.g. near doors, windows, air conditioning units or fans]
These units require good airflow inside and outside. It is essential the
vents in the external panels do not become blocked as this can cause
the unit to fail, due to overheating. Internally good air flow must also be
maintained, a small space should be left between all products.
The condensing coil & vents requires
regular cleaning to maintain the
performance of the unit, as air borne
particles will choke the coils fins.
They should be cleaned with a soft
brush and vacuum.