18
INSTRUCTIONS FOR THE INSTALLER
SAFETY ADVICE
•
Before installation ensure that the local
distribution conditions (gas type and
pressure) and the pre-setting of the
appliance are consistent.
•
This appliance must be installed only in a
room with good ventilation.
•
This appliance must not connected to a flu. It
has to be installed and connected in
accordance with the rules in force. Special
attention should be paid to the applicable
disposal concerning ventilation.
•
The adjacent furniture panels have to be heat
proof or protected by such material.
•
The adjusting conditions of this appliance are
mentioned on the rating plate.
Connection to gas supply.
Check that the gas flow and the diameter of the
supply pipe is sufficient to supply all the
appliances of the installation
.
•
Check that all connections are tight.
•
Install an accessible and visible gas tap to
isolate the appliance.
ELECTRIC CONNECTION
Any electrical work required to install
this cooker should be carried out by a
qualified electrician or competent person, in
accordance with the current regulations.
This cooker must be earthed.
This cooker is designed to be connected to a
240V 50Hz AC electrical supply.
Before switching on, make sure the electricity
supply voltage is the same as that indicated on
the rating plate.
Check on the rating plate the value for the
total connection power for establishing the
fuse power.
Fuse capacity: 5 A
If the supply cable is damaged it must be
replaced by the manufacturer or its
service agent.
Before connecting check that:
•
The plug used for connection is easily
accessible when the appliance is installed.
-
Installation of flues and ventilation for gas
appliances of rated input not exceeding
60 kW (1
st
, 2
nd
and 3
rd
family gases) – Part
2 Specification for installation of
ventilation for gas appliances – BS 5440;
-
Gas burning appliances – Part 3 Domestic
cooking appliances burning gas – BS
5386;
-
Specification for installation of low
pressure gas pipe work of up to 20mm
(R1) in domestic premises (2
nd
family gas)
– BS 6891;
-
Pipe threads for tubes and fittings where
pressure-tight joints are made on the
threads (metric dimensions) – BS 21:
1985;
-
Flexible hoses, end fittings and sockets
for gas burning appliances – BS 669;
Installation of domestic gas cooking
appliances (1
st
, 2
nd
and 3
rd
family gases) – BS
6172: 1990;
Warning
The supply cable must not be routed across
the back of the oven.
power cord
YES
NO
power cord
Содержание GSC 5062
Страница 1: ...GAS COOKER GSC 5062 GB...
Страница 2: ...2...