17
INSTRUCTIONS FOR THE INSTALLER
Safety Advice
This cooker must be installed in accordance
with the IEE Wiring Regulations (Current
Edition).
Detailed recommendations are contained in the
following British Standards Codes Of Practice:
B.S. 6172/ B.S. 5440, Par. 2 and B.S. 6891
Current Editions.
Location
This cooker has been registered as a "Class X"
appliance according to Fire Risk Regulations.
Any adjacent cabinets or walls must not exceed
the cooker's height.
The cooker may be located in a kitchen, a
kitchen/diner or bed sitting room, but not in
a bathroom or shower room.
The minimum distance combustible material can
be fitted above the cooker in line with the edges
of the cooker is 420 mm. If it is fitted below 420
mm. a space of 50 mm. must be allowed from
the edges of
the cooker.
The minimum distance combustible material can
be fitted directly above the cooker is 700 mm.
The adjacent furniture panels have to be
heat proof or protected by such material.
TECHNICAL DATA
Dimensions
Height
Depth
Width
Oven Capacity
Hob
Front left heating plate
(rapid)
Back left heating plate
(normal)
Back right heating plate
(normal) Front right
heating plate (normal)
Total Rating
900mm
500mm
600mm
1.942 Cu. ft
2000 W
1000 W
1500 W
1000 W
5500 W
Oven
Conventional (both
elements)
Top element
Bottom element
Supply voltage (50Hz)
1750 W
750 W
1000 W
230-240 V