![Moen GEC 5 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/moen/gec-5/gec-5_owners-manual_1819805005.webp)
5
NBUF IN
2- Signal Path
N1
N3
LOOP4
N2
LOOP3
OUT
TUNER
BUF OUT
LOOP5
IN5
POOL
BUF IN
3- Presets Hierarchy
GEC5 have 128 presets, which are contained in 32 banks, each bank have 4 presets,
the banks are contained in 8 pools (A~H), each pool have 4 banks.
A
B
C
D
E
F
G
H
A
1
A
2
A
3
A
4
BANK
PRESET
H
1
H
2
H
3
H
4
The first preset number (midi program change number 0) is bank A1, preset 1.
The last preset number(midi program change number 127) is bank H4, preset 4.
4- Recall Presets, Change BANK, Change POOL
Press footswitch 1/2/3/4 to recall presets, the corresponding LED lights on when
a preset is engaged. To recall a preset in another bank, press BANK switch once
till the bank number starts to blink, and press BANK switch again to find the bank
number then press footswitch 1/2/3/4 to recall expected presets. To recall a preset
in another pool, need to hold the BANK switch for 2 seconds till the pool index
starts to blink, then press BANK switch again to find the pool then press footswitch
1/2/3/4 to recall the expected presets.
5- Control Loops
“
On The Fly
”
User could recall a preset, then double click BANK (press twice fastly, before it
changes the bank number) to enter
“
On The Fly
”
mode, the screen shows
“
”
,
this mode allows the loops to be controlled individually by preset switch 1/2/3/4
and mute switch. preset 1 switch turns on/off loop5, preset 2 for loop4, preset 3 for
loop3, preset 4 for loop green, MUTE for loop Blue.
“
On The Fly
”
is very useful for
rehearsal, or adding/removing a few pedals individually. Click BANK again to exit.
OUT5
Sequential loop green and blue could be at any place of N1 or N2 or N3, or bypass,
however, the two sequential loops can not be engaged at the same place.