RETAINER
CLIP
CARTRIDGE
NOTCH
WASHER
STOP TUBE
KEY STOP
TEMPERATURE
LIMIT STOP
KNOB
HANDLE
HANDLE
ADAPTER
CAP
SCREW
HANDLE
SCREW
HANDLE
SCREW
KNOB
INSERT
PLUG BUTTON
HOT INLET
FORWARD
COLD INLET
TO REAR
INSTALL WITH
CARTRIDGE
STEM NOTCH
DOWN
TOP VIEW
CAUTION: CARTRIDGE
MUST BE INSTALLED
WITH HOT & COLD
INLETS AS SHOWN
FRONT VIEW
CAUTION: CARTRIDGE MUST BE INSTALLED
WITH HOT & COLD INLETS AS SHOWN
LEVER
HANDLE
LEVER
HANDLE
Disassembly
Turn "OFF" both hot and cold water supplies, then rotate handle counterclockwise until the lever points straight up to relieve pres-
sure. Remove handle parts.
1. For handle style A + B , remove handle insert or plug button. Take out handle screw, remove handle and washer.
For handle style C , remove cap screw and handle. Remove handle screw and handle adapter.
2. Remove temperature limit stop, key stop and stop tube. Lift out retainer clip.
Rotate cartridge shell between the Eleven and One O'Clock position with Moen cartridge twist wrench, grasp the
cartridge stem with pliers, and pull out the cartridge.
Reassembly
Properly orient the cartridge, see illustration above, then re-insert cartridge by pushing it all the way into the body until the front of the ears on the cartridge
shell are flush and aligned with the top and bottom of the valve body. Replace the retainer clip so that the legs straddle the cartridge ears and slide down into
the bottom slot in the body. This prevents the cartridge from rotating and locks it in the body. Reinstall stop tube and parts. Limit stop must be installed with
offset at TOP (12 o'clock) position to obtain maximum hot water. The notched flat on the stem must point DOWN when mounting the handle.
To Adjust Temperature Limit Stops
CAUTION:
Due to seasonal temperature change of the cold water supply, the temperature limit must be readjusted accordingly to maintain
the desired maximum discharge temperature.
1. Rotate the handle counterclockwise to the stop, let the water run for several minutes to purge cool water from the hot water supply line, check
the hot water temperature.
2. Rotate handle clockwise to off. Remove handle parts, see "Disassembly" and temperature limit stop, rotate the stop clockwise to decrease
(counterclockwise to increase) maximum hot water temperature and reinstall into key stop.
3. For handle styles A & B replace handle, for style C replace handle adapter, do not use handle screws.
4. Rotate the handle or handle adapter counterclockwise to the stop, recheck maximum hot water temperature.
5. Repeat steps 2,3 & 4 until desired maximum temperature is achieved. Install handle parts, see Handle Attachment under "Trim" on following page.
KEY STOP
TEMPERATURE
LIMIT STOP
ROTATE LIMIT
STOP CLOCKWISE
TO REDUCE
FULL HOT POSITION
C
B
A