background image

RETAINER

CLIP

CARTRIDGE

NOTCH

WASHER

STOP TUBE

KEY STOP

TEMPERATURE

LIMIT STOP

KNOB

HANDLE

HANDLE

ADAPTER

CAP

SCREW

HANDLE

SCREW

HANDLE

SCREW

KNOB

INSERT

PLUG BUTTON

HOT INLET
FORWARD

COLD INLET

TO REAR

INSTALL WITH

CARTRIDGE

STEM NOTCH

DOWN

TOP VIEW

CAUTION: CARTRIDGE 

MUST BE INSTALLED

WITH HOT & COLD

 INLETS AS SHOWN

FRONT VIEW

CAUTION: CARTRIDGE MUST BE INSTALLED

WITH HOT & COLD INLETS AS SHOWN

LEVER

HANDLE

LEVER

HANDLE

Disassembly

Turn "OFF" both hot and cold water supplies, then rotate handle counterclockwise until the lever points straight up to relieve pres-
sure.  Remove handle parts. 
1.  For handle style  A  +  B  , remove handle insert or plug button. Take out handle screw, remove handle and washer.

For handle style   C  , remove cap screw and handle.  Remove handle screw and  handle adapter.

2.  Remove temperature limit stop, key stop and stop tube. Lift out retainer clip.

Rotate cartridge shell between the Eleven and One O'Clock position with Moen cartridge twist wrench, grasp the  
cartridge stem with pliers, and pull out the cartridge. 

Reassembly

Properly orient the cartridge, see illustration above, then re-insert cartridge by pushing it all the way into the body until the front of the ears on the cartridge
shell are flush and aligned with the top and bottom of the valve body.  Replace the retainer clip so that the legs straddle the cartridge ears and slide down into
the bottom slot in the body.  This prevents the cartridge from rotating and locks it in the body. Reinstall stop tube and parts. Limit stop must be installed with

offset at TOP (12 o'clock) position to obtain maximum hot water. The notched flat on the stem must point DOWN when mounting the handle.

To Adjust Temperature Limit Stops

CAUTION: 

Due to seasonal temperature change of the cold water supply, the temperature limit must be readjusted accordingly to maintain

the desired maximum discharge temperature.

1. Rotate the handle counterclockwise to the stop, let the water run for several minutes to purge cool water from the hot water supply line, check 

the hot water temperature.

2. Rotate handle clockwise to off. Remove handle parts, see "Disassembly" and temperature limit stop, rotate the stop clockwise to decrease

(counterclockwise to increase) maximum hot water temperature and reinstall into key stop.

3. For handle styles  A  &  B  replace handle, for style  C  replace handle adapter, do not use handle screws.
4. Rotate the handle or handle adapter counterclockwise to the stop, recheck maximum hot water temperature.
5. Repeat steps 2,3 & 4 until desired maximum temperature is achieved. Install handle parts, see Handle Attachment under "Trim" on following page.

KEY STOP

TEMPERATURE

LIMIT STOP

ROTATE LIMIT

STOP CLOCKWISE

TO REDUCE

FULL HOT POSITION

C

B

A