Moeller Marine EASY 400 Скачать руководство пользователя страница 4

Lighting for shop windows:

• Automatic daylight- and clock-controlled switching of

lighting and external  advertising shows products in a 
“favourable light”. 

• Lighting can be activated in the event of an alarm or at

random.

• Program protection via password.
• Supply and input voltage 100 to 240 V AC. 

Direct  switching of the load current via relay. 
Direct connection of, for example, standard recessed 
switches to  easy. 

Using easy 

Showing Your Business 

in a Favourable Light

Greenhouses:

• Daylight- and temperature governed control of           

skylights, heating, blowers, watering and lighting.

• Recording and processing of up to four analog values 

such as temperature, humidity or brightness. 

• Processing, comparison, display and output of the 

analog values via convenient arithmetical functions 
and analog output.

• Setting of required values directly at the device.
• Manual intervention possible at any time via external 

switches or the four built-in cursor keys.

Lighting control for buildings:

• Both centralized and decentralized impulse-relay 

function switching of lights is possible.

• A real-time controlled Off pulse enables central 

disconnection of the lighting for power saving 
purposes. 

• A basic unit can control up to 12 separate groups of 

lighting. Convenience lighting control such as that of
a central light for cleaning, semi-lighting in the stair 
well or a pulse for pre-warning of a dark phase can
be configured.

• Suitable for fitting in low-voltage distribution boards 

due to 45 mm standard front dimension, and either 4,
6, 8 or 12 times MCB width.

ea y

s

MO-FR

13.03       1

ON        08:40    A

OFF        19:30    +

X          

00.00

S           17.13      

TRG   

T1

RES +

A  01  GT               +  

I1   +580      

F1  +   10

I2   + 5000

Содержание EASY 400

Страница 1: ... x 118 5 mm 222 Logo 17 x 17 mm Industrial Automation Building Automation Systems Think future Switch to green The easy400 600 800 control relays Product Information Switching Control and Communication SIMPLY ea y s ...

Страница 2: ...tor Great space savings There is space for easy anywhere The standard 45 mm front dimension is equally suitable for use in service distribution boards in building services installations or in control panels on machines and in industrial control systems In each case the easy replaces several conventional components and switching devices in a fraction of their space requirement easy One for all The ...

Страница 3: ...alogue output The easy800 has four contacts and one coil in series for circuit configuration in each of up to 256 lines of logic The built in display can show up to 32 texts of 64 characters each For each text the user can include several variables or module parameters in the display at any point He can thus read texts and values on the display in plain text Counting high speed signals measuring f...

Страница 4: ...he analog values via convenient arithmetical functions and analog output Setting of required values directly at the device Manual intervention possible at any time via external switches or the four built in cursor keys Lighting control for buildings Both centralized and decentralized impulse relay function switching of lights is possible A real time controlled Off pulse enables central disconnecti...

Страница 5: ...ent changes to the circuit diagram which may be necessary can be undertaken off site the memory module sent to site and the modifications read into the easy there Adjustable start up behaviour RUN or STOP which then governs the operating mode when the power is switched on facilitates commissioning Detection of short circuits and selective disconnection of the transistor outputs in the event of sho...

Страница 6: ...ocessing its own program or being used merely as a remote input output module Furthermore each easy800 device can be locally expanded via the easy Link interface This feature enables easy control relays to be used throughout automation applications of from 12 to more than 300 I O points Networking easy With Built in NET Communication simplified The operator can monitor the entire network from the ...

Страница 7: ... fieldbus systems such as Profibus DP are used for more complex automation tasks in which the user has to transfer relatively large sets of data e g several analog values setpoint values counter readings or time parameters Profibus DP can transfer up to 20 Bytes per station in each bus cycle and can link up to 126 stations at distances of up to 1200 m This bus connection the EASY204 DP makes easy ...

Страница 8: ...ese three expansion modules are linked directly to the basic unit via the easy Link interface Alternatively connection can be achieved via the EASY200 EASY coupling module and a simple twisted pair cable up to 30 m in length Even complex and extensive circuits can thus be achieved simply using easy In the event that you need still more I O the EASY202 RE module offers another two relay outputs Loc...

Страница 9: ...t I2 Enter contact I1 Connect up contact and coil Select relay coil Q1 Each of the eight selection buttons has its own specific function The OK button activates the selected function The four cursor keys up down left and right allow the user to make his selection from the actions to be taken The ESC button reverses the action and the DEL button erases The ALT button is used to make the logic conne...

Страница 10: ...s Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes of outputs 1 8 A 8 A 8 A 8 A 8 A 8 A 0 5 A 0 5 A 8 A 8 A 8 A 8 A 8 A 0 5 A 0 5 A 8 A 8 A 8 A 8 A 0 5 A 0 5 A 8 A 8 A 0 5 A 0 5 A 8 A 8 A 0 5 A 8 A Potential isolation primary secondary Yes SELV to EN 60 0950 VDE 805 Yes SELV to EN 60 0950 VDE 805 Short circuit proof where cos phi 1 B 16 600 A B 16 600 A Protection against short circuit ...

Страница 11: ...nd without the module being connected Notes alongside contacts and coils create clarity A cover sheet with your own title block various text boxes and cross reference list with comments make your print out into a professional piece of documentation Easy needs no maintenance Once the program is designed it is stored in the easy in a non volatile fashion and retained there forever or until the next ...

Страница 12: ...r is your competent partner for building automation industrial automation and power distribution We provide a complete package or individual combinations depending on your application And everything fits together perfectly core products PLCs data and process display units communication products software standards accessibility via the Internet design and solution competence and professional servic...

Отзывы: