Operation

 

Once installed using the above instructions, your AF

-

10XXVT air cleaner(s) can be operated with the flip of a switch. 

Because the AF

-

10XXVT series is designed as an 

Air quality Maintenance

” 

system, it is important that the units are 

turned on in the beginning of the shift and left on until the end of the shift. The reason the units need to remain on is 
because Air Cleaners train the air current throughout the entire area in order to ensure that all of the air is cycling 
through the filters. The process of training the air can take a while, but is usually about 30 minutes.

 

 

Maintenance

 

Follow these precautions when performing maintenance on the motor or blower. 

 

Turn off motor, and LOCK OUT electrical service to the unit.

 

LOCK OUT even when changing filters.

 

Change filters regularly to maintain optimum performance. If the performance of your air cleaners appears to be 
declining, try replacing the filters.

 

Be sure that replacement filters are always rated for the correct CFM and air flow.

 

 

NOTE FOR INSTALLING BAG FILTERS: 

 

When installing fiberglass bag filters, MAKE SURE THAT NO FABRIC IS PINCHED BETWEEN THE HEADER 
AND FILTER FRAME.  

Performance will decrease dramatically if bag filters are not properly installed.  To ensure no 

fabric is pinched, place your fingers inside each cell, and gently move each bag cell side to side, freeing any fabric 
sandwiched between the header and filter frame.

  

 

 

If the system requires maintenance exceeding filter change, read below

 

Take the unit down and place it on a level surface that allows access to the access panels on each side of the Main 
Housing. 

To access the motor, pulleys and belt:

 Remove the door panel by removing (20) 1/4

-

20 bolts with a 3/8 

socket. 

 

Troubleshooting Chart

 

Symptom

 

Possible Cause(s)

 

Corrective Action

 

Excessive belt noise

 

1. Belt is loose

 

1. Remove back panel, loosen nuts that fasten motor, 
turn adjustment screw until optimum belt tension is 
achieved

 

  

2. Belt is worn out or glazed.

 

2. Follow step (1) to loosen belt, put new belt on and the 
reverse step (1) to tighten belt and re

-

assemble

 

Air cleaner is not working 
very well, and filters are not 
getting dirty.

 

1. It

s possible that the air cleaner 

may have been wired backwards 
upon installation.  Air will blow out 
the exhaust either way, but if wired 
correctly it should blow at about 58 
mph.

 

1. If the motor is wired to run the wrong direction, dis-
connect power supply, & switch the necessary wires 
around to reverse the motors rotation with the voltage 
you are using.

 

  

2.  The bag filter may not be seated 
properly

 

2. Reach in each pocket to make sure fabric is not be-
tween filter stop and filter frame.

 

Air is not staying as clear as 
usual

 

1. Prefilters may be loaded with 
debris

 

1. Turn unit off, lock out power to unit, then replace the 
prefilter by pushing clips out of the way and then sliding 
it out and sliding a new one in.

 

  

2. Bag filter may be spent

 

2. Follow step (1) to remove the prefilter, then if unit is 
equipped with clips, push them out and away from the 
bag filter, slide out the old bag filter and slide in new one 
until clips snap around it.

 

Содержание AF-10X3VT Series

Страница 1: ...ir Cleaner was designed for use as ambient air filtration where airborne particles are prevalent The air cleaner consists of two intakes and one exhaust one motor one blower electrical components and...

Страница 2: ...er frame If the system requires maintenance exceeding filter change read below Take the unit down and place it on a level surface that allows access to the access panels on each side of the Main Housi...

Страница 3: ...sts like aluminum magnesium and other materials NFPA also has standards that cover other dusts like grain and plastics ect For guidelines on determining which precautions should be taken please refer...

Страница 4: ...shall be held liable for direct or consequential damages resulting from improper methods structural failure or inadequate supports Installation Diagram on PG 5 Installation methods will depend upon t...

Страница 5: ...e Installation Guide For a more detailed description see page 4 USE CONNECTOR NUTS ON THE 4 STUDS PROVIDED AT THE TOP OF THE UNIT AS SHOWN CONNECT NUTS TO THREADED ROD TO SUSPEND THE UNIT WITH SUPPORT...

Страница 6: ...6 Tanis Technologies 10VT Series Filtration Unit Revised 6 30 2020...

Страница 7: ...7 Tanis Technologies 10VT Series Filtration Unit Revised 6 30 2020...

Страница 8: ...to be defective in material or workmanship can be shipped prepaid to Tanis Technologies or authorized service facility in which case a determination will be made whether to repair or replace the comp...

Отзывы: