2 PREPARING FOR INSTALLATION
Before using the appliance for the first time, remove all the protection sheets, clean all the
surfaces with a soft cloth, warm water and soap to remove all traces of the antirust
products applied during production.
To install the appliance close to walls, partitions, kitchen units, decorative claddings, etc.,
they ought to be made with non flammable materials or leave a gap of at least 100 mm
between them and the appliance.
It is essential to comply with the fire prevention rules.
The main switch and outlet must be near the appliance and easy to reach.
Level the appliance, adjust its height and stability by turning the levelling feet.
2.1 LAWS, TECHNICAL REGULATIONS AND GENERAL GUIDELINES
Comply with the following rules during installation:
1) accident prevention standards;
2) the laws in force in the country where the appliance is installed;
3) read all the indications given in this handbook carefully as they provide important
information for safe installation, use and maintenance;
4) keep this handbook in a safe place for future reference by those who use the
appliance.
2.2 INSTALLATION
Only specialised personnel
should install, start and service the appliance.
Installation must be carried out in compliance with the laws in force in the country where
the appliance is installed.
The manufacturer declines all responsibility if the appliance malfunctions due to incorrect
installation, tampering, improper use, bad maintenance, failure to comply with the local
laws and inexperience in using the appliance.
2.2.1 ELECTRICAL CONNECTION
1)
The
heating elements are delivered set up operation with a voltage of
VAC 230+1.
2) Connect to the electricity line, interposing a suitably rated automatic circuit breaker,
where the opening distance between the contacts must be at least 3mm. Furthermore,
supply voltage must not deviate from the voltage value by ± 10%. The flexible cable
which is installed for connection to the electrical mains has H05RN-F rubber insulation
and a nominal cross-section which is adequate for maximum current input.
3) It is essential that the appliance is connected to an effective earth plug. For this
purpose, near the connection terminal board there is a terminal marked with a plate
with the symbol on it and to which the earth wire must be connected (yellow-green).
This wire must be long enough so that, if the cable relief strain slackens, it can only be
stressed after the power wires have been disconnected.
NOTE: earthing must comply with current laws.