5.

  

PCCU-100 IS RATED FOR 115 VAC 60 Hz OPERATION

.  Use the 

inverter only to power appropriate appliances rated for this power input . 
 

6.

  

PCCU-100 IS RATED TO POWER LOADS OF 50 WATTS 

CONTINUOUS

.  Do not connect high power loads (> 50 W) to your 

inverter. 
 

7.  TO REDUCE USE OF ELECTRIC SHOCK

 always unplug any 

appliances from the PCCU-100 and remove the battery pack from the 
inverter before cleaning or maintaining the inverter or any appliance.  
Use of a Ground Fault Circuit Interrupter between the inverter output and 
the appliance is recommended to reduce shock hazards. 
 

8.  DO NOT DISASSEMBLE

.  The PCCU-100 contains no user 

serviceable parts and should not be disassembled under any 
circumstances.  If faulty operation is suspected, return the inverter for 
inspection and service if required. 
 

9.

  

NEVER CONNECT THE PCCU-100 TO AC DISTRIBUTION 

WIRING

.  Connect the 115 VAC inverter output directly to the appliance 

to be powered, preferably using a GFCI power cord / module. 
 

10.

  

STORE INVERTER IN A COOL, DRY PLACE

.  Avoid leaving the 

inverter in direct sunlight, vehicle cabs, compartments, or unventilated 
storage buildings during hot summer conditions.  Under extreme 
temperature conditions damage may occur.  Avoid allowing inverter to 
become wet or damp.  Allow damp or wet inverter to dry thoroughly 
before using.

  

 
11.

  

TURN PCCU-100 OFF AND REMOVE BATTERY PACK

 when not 

in use. 
 

12.

  

REPLACE FUSE ONLY WITH 10A 32V BLADE FUSE.

  

 
 

WARNING

 

READ AND SAVE THESE INSTRUCTIONS FOR 

FUTURE USE.

 

Failure to follow all instructions may result in electrical shock, fire, 

equipment damage, and/or serious personal injury. 

FUNCTIONAL DESCRIPTION 

 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
If a battery pack is too hot or too cold, it will not power the PCCU-100 
module.  The lighted on/off power switch will illuminate when turned to 
the on position with a charged battery within temperature limits attached.  
If the switch does not illuminate, check that the fuse is intact and that the 
battery does not show an error condition when connected to a CHG-50 
charger.  If the switch still does not illuminate, the PCCU-100 should be 
retired from service and sent for inspection and repair if needed. 

LIGHTED POWER 

ON/OFF SWITCH 

115 VAC 60 Hz 

POWER 

RECEPTACLE

FUSE 

BATTERY 

CONNECTOR 

INFORMATION 

LABEL 

(NOT VISIBLE) 

PCCU-100 

24 Volt 

Lithium Ion

 

Battery 

to 115 VAC 60 Hz 

Power Conversion and Control Unit

Содержание PCCU-100

Страница 1: ...umstances connect the PCCU 100 to power sources or other equipment not specifically and expressly designated for use with this model inverter 2 AVOID DANGEROUS CONDITIONS AND ENVIRONMENTS Do not connect a battery pack or operate the PCCU 100 in damp or wet conditions Avoid using the inverter in direct exposure to rain or snow Do not use the battery pack or inverter in the presence of explosive gas...

Страница 2: ...abs compartments or unventilated storage buildings during hot summer conditions Under extreme temperature conditions damage may occur Avoid allowing inverter to become wet or damp Allow damp or wet inverter to dry thoroughly before using 11 TURN PCCU 100 OFF AND REMOVE BATTERY PACK when not in use 12 REPLACE FUSE ONLY WITH 10A 32V BLADE FUSE WARNING READ AND SAVE THESE INSTRUCTIONS FOR FUTURE USE ...

Страница 3: ... depleted and the PCCU 100 is about to or has shut down ALWAYS ASSUME HIGH VOLTAGE IS PRESENT AT THE POWER RECEPTACLE Turn off the PCCU 100 before plugging or unplugging appliances or battery packs 5 External fuse The PCCU 100 has a fuse protecting against input battery over current conditions The SIPS TM Scalable Intelligent Power Systems components are designed to shutdown electronically in adva...

Страница 4: ...CU 100 Inverter with EM 100 Lithium Ion Battery Pack 7136 Eagle Rd Willoughby OH 44094 9636 Tel 440 942 2133 Fax 440 942 2480 support modtech corp com Copyright 2008 Modtech Corp All rights reserved 8 NOTES ...

Отзывы: