![Modernum Smart 20 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/modernum/smart-20/smart-20_user-manual_1817908004.webp)
1.2Ah: 1.5h 7Ah: 6h 12Ah: 9h 20Ah: 15h
Notes: min charge time is 6h. If left connected after step 5, it
is programmed to restart from Step1 after 7 days, to refresh
the battery.
SPECIAL FEATURES
Temperature sensor:
The temperature affects the batteries
ability to receive charge. This product has a sensor in the
battery cable connector, which compensates for
temperature variations to give optimal charge in cold as well
as warm conditions, avoiding the common problem of
insufficient charging in cold weather and over-charging at
high temperatures.
Storage and travel
: To make it easy to bring the charger with
you, and for compact storage, you can wind the cables
around the charger’s holders in the back and front, and then
lock them together with the included strap.
FAULTS INDICATIONS & TROUBLE-SHOOTING
1.
Fault
: Charging does not start , i.e. green light
does not change from quick to slow flashes, when
battery is connected.
Probable cause 1
: Reversed polarity.
Action
: disconnect charger from the mains, re-
connect the clamps correctly, connect charger to
mains again.
Probable cause 2
: Clamps do not have good
connection to battery.
Action
: Check that clamps are connected well to
metal on both battery poles. Check that
connector on the clamp cable is pushed all the
way into connector on charger’s connector.
Probable cause 3
: The battery voltage is too low
for the charger to detect it, and it will not start.
This may be because the battery is worn or faulty
or has been overly discharged.
Action
: You can try to connect another battery in
parallel, like when using jump-start cables:
Disconnect the charger, and then connect the
batteries to each other by connecting their
positive terminals (+) together using a jumper
cable, and then connecting the negative terminals
(-) using another jumper cable. Then connect the
charger and retry the process. If charging starts,
disconnect the jumper cables and let charging
continue until battery is fully charged. If the
charging does not begin the battery is probably
defective and should be replaced.
MAINTENANCE
The charger is entirely maintenance-free. It has no user-
serviceable parts. Opening the charger will void the