background image

SERIAL NUMBER:________________________________________

Landscape Pro Slim Series

LPS-4414 • LPS-5614 • LPS-6814 • LPS-8014 • LPS-9614

INSTALLATION/OWNERS MANUAL

FOR USE IN UNITED STATES AND CANADA

Содержание Landscape Pro Slim Series

Страница 1: ...SERIAL NUMBER ________________________________________ Landscape Pro Slim Series LPS 4414 LPS 5614 LPS 6814 LPS 8014 LPS 9614 INSTALLATION OWNERS MANUAL FOR USE IN UNITED STATES AND CANADA ...

Страница 2: ...esulting in serious injury and or property damage WARNING All electric heaters have hot and arcing or sparking parts inside Do not use it in areas where gasoline paint or flammable liquids are or are stored This fireplace meets the construction and safety standards of H U D for application in manufactured homes when installed according to these instructions INSTALLER Leave this manual with the app...

Страница 3: ...8 To prevent a possible fire do not block air intakes or exhaust in any manner 9 A heater has hot and arcing or sparking parts inside Do not use it in areas where gasoline paint or flammable vapors or liquids are used or stored 10 Use this heater only as described in this manual Any other use not recommended by the manufacturer may cause fire electric shock or injury to persons 11 SAVE THESE INSTR...

Страница 4: ...5RPM CCW AC120V 60Hz 40mA 3 7W 18 15RPM CCW Shipping Size 46 1 4 x 26 x 8 58 1 4 x 26 x 8 70 1 4 x 26 x 8 82 1 4 x 26 x 8 98 1 4 x 26 x 8 Model Viewing Area Firebox Dimensions Framing Dimensions LPS 4414 43 3 4 W x 14 H 44 1 4 W x 23 3 4 H x 5 1 2 D 44 1 2 W x 24 1 8 H x 6 D LPS 5614 55 3 4 W x 14 H 56 1 4 W x 23 3 4 H x 5 1 2 D 56 1 2 W x 24 1 8 H x 6 D LPS 6814 67 3 4 W x 14 H 68 1 4 W x 23 3 4 ...

Страница 5: ...5 INSTALLATION BOX CONTENTS 1 Fire Unit 1 Remote 4 L Metal Mounting Brackets 1 Trim Kit 1 Glass Face Logs Acrylic Media 1 Owner s Manual ...

Страница 6: ... curtains at least 3 feet 0 9m from the front of the heater and keep them away from the sides and rear CAUTION Wear gloves and safety glasses for protection during installation and maintenance This fireplace can be installed fully recessed or half recessed To prepare for installation connect the hard wire to the terminal block according to the diagram below Choose any connector type according to l...

Страница 7: ...de a dedicated flexible 15 amp 120 volt circuit for hard wire installation 2 Install L Metal Nailing Flanges to the fireplace 3 Install the fire unit in the framed opening with a minimum 1 drywall screws to secure the unit 4 Mask the exposed fire unit during the drywall process Install drywall to the drywall stops on the perimeter of the fire box For more information on the drywall stops see the P...

Страница 8: ... installation is optimized for a 2x4 framed wall Prepare the framed opening according to the chart on page 7 Provide a dedicated flexible 15 amp 120 volt circuit for hard wire installation 2 Install L Metal Nailing Flanges to the fireplace 3 Install the fire unit in the framed opening with a minimum 1 drywall screws to secure the unit 4 Mask the exposed fire unit during the drywall process Install...

Страница 9: ...he fire is energized The status light above shows that the power is on and the heater is on low 2500 BTU The status light above shows that the power is on and the heater is on high 5000 BTU Pairing remote wall mounted touch control 1 With the fireplace ON press and hold the Power button for about 3 seconds until you hear the buzzer sound twice and the power indicators begin to flash 2 Within 5 sec...

Страница 10: ...NSFORMER MF PRO WIFI WIFI WIFI BOARD MF PRO HF HEATER FAN 120 V MF PRO PTC PTC HEATER 120 240 V 1500 3000 WATTS MFSM120 SPINDLE MOTOR 120 V 50 60 HZ MF PRO RC PRO SERIES RF REMOTE CONTROL MF PRO WTC OPTIONAL WALL MOUNTED TOUCH CONTROL ASSEMBLY MF PRO TB TERMINAL BLOCK 120 240 V MF PRO MTC MANUAL TOUCH CONTROL BOARD MFPS2 20 AMP POWER SWITCH ...

Страница 11: ...PS F LED 56 MF LPS F LED 68 MF LPS F LED 80 MF LPS F LED 96 MF LPS EB DL 44 RGB EMBER BED DOWNLIGHT LED STRIP MF LPS EB DL 56 MF LPS EB DL 68 MF LPS EB DL 80 MF LPS EB DL 96 MF LPS SR 44 SPINDLE ROD FOR FLAME OR EMBER BED MF LPS SR 56 MF LPS SR 68 MF LPS SR 80 MF LPS SR 96 MF LPS GF 44 FRONT GLASS MF LPS GF 56 MF LPS GF 68 MF LPS GF 80 MF LPS GF 96 MF LPS PP 44 POLY SCREEN MF LPS PP 56 MF LPS PP 6...

Страница 12: ...eated and safety disc has snapped or circuit breaker has tripped A Turn the main breaker to the off position for 30 seconds Next flip the breaker back into the on position Can operate fireplace functions with manual controls but not remote control A Low Batteries A Replace batteries in remote control with CR2025 B Remote not paired properly B With the fireplace ON press and hold the Power button f...

Страница 13: ... remote need to be replaced A Annually possibly more with heavy use Q Is there a remote receiver in the fireplace that requires batteries A No only the actual remote requires batteries The rest of the fireplace runs entirely off of the main power supply Problem Possible Cause Corrective Action Flame is not visible when unit is turned on A Wiring is loose A Disconnect unit from power source and ins...

Страница 14: ...ires that may be exposed as you do this To clean the glass face of the fireplace simply use your desired glass cleaner with paper towels To clean the air inlets outlets wipe with a soft cloth or the nozzle of a vacuum cleaner Dust can easily build up around the heater area inside the fire unit on the left and right sides Take particular care to clean this area on a regular basis to prevent buildup...

Страница 15: ...15 MAINTENANCE NOTES ...

Страница 16: ...16 2019 www modernflames com Please dispose of properly V1 ...