MAINTENANCE 

MAINTENANCE 

PROBLEM 

POSSIBLE CAUSE 

CORRECTIVE ACTION 

Nothing comes on (touch 
screen, etc.) 

A. Fireplace is not plugged in to an 
electrical outlet 

A. Check plug 

B. Breaker tripped or outlet has no 
power 

B. Reset breaker, test outlet for 
power 

C. Power Switch is not in the “On” 
position (bottom right) 

C. Turn main power switch to the 
“On” position  (solid white line is 
flush with the fireplace) 

D. Internal component is frozen 
and needs to be reset 

D. Turn unit off and unplug for 5 
minutes. Plug back in and turn unit 
on. If plug cannot be reached, reset 
breaker and turn unit back on 

E. Defective component 

E. Qualified service technician 
needs to replace motherboard, 
transformer or LCD touch control 

Touch Screen Comes on 
- then nothing 

 

A. Fireplace is not plum to the wall 
(there is space between the touch 
screen and fascia) 

A. Reposition the fireplace in the 
installation so the glass fascia rests 
firmly to the fireplace touch controls. 
Check that fascia is seated correctly 
on pins 

B. Fireplace was installed with the 
power in "on" position 

B. Turn main power switch to the 
"off" position for 30 seconds. Switch 
the fireplace back into the "on" 
position for 20 seconds for complete 
reboot of touch control. 

C. Not operating touch control 
properly with finger 

C. Press flat part of finger firmly on 
the touch screen and apply 
moderate pressure 

D. Loose connection on 
motherboard 

D. Check functions with remote 
control. if functional, check 
connections on motherboard 

E. Motherboard is defective 

E. Replace Motherboard 

Fireplace turns off and 
will not turn back on 

A. Fireplace has overheated and 
safety disc has snapped or circuit 
breaker has tripped 

A. Turn off major power switch and 
waiting 5 minutes to turn it back on 
or reset circuit breaker 

A. Low Batteries 

A. Replace batteries in remote 
control with - 2 AA batteries 

Can operate fireplace 
functions with touch 
controls but not remote 
control 

B. Not aiming control correctly 

B. Aim remote control to the upper 
right of the viewing area where 
sensor is located 

C. Remote control defective 

C. Replace remote control  

D. Remote Sensor is defective 

D. Replace remote sensor inside 
fireplace 

Содержание HF1200CBI

Страница 1: ...Home Fire CBI Electric Series HF900CBI HF1200CBI HF1500CBI INSTALLATION SERVICE INSTRUCTIONS FOR USE IN UNITED STATES AND CANDA ...

Страница 2: ...ctric heaters have hot and arcing or sparking parts inside Do not use it in areas where gasoline paint or flammable liquids are or are stored This fireplace meets the construction and safety standards of H U D for application in manufactured homes when installed according to these instructions INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference ...

Страница 3: ...over 10 To disconnect heater turn controls to the OFF before removing plug from outlet 11 Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire or damage the heater WARNING Improper installation adjust ment alteration service or maintenance can cause injury or property damage Refer to this manual For assistance or additional ...

Страница 4: ...door down to open 23 Do not let children play with the appliance unsupervised 24 Heater must not be located immediately below a socket outlet 25 The appliance is not to be used by children or persons with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision and instruction 26 If the supply cord is damaged it must be replaced by...

Страница 5: ... Viewing Area Face Dimensions Firebox Dimensions HF900CBI 762mm W x 445mm H 914mm W x 743mm H 821mm W x 681mm H x 291mm D HF1200CBI 914mm W x 445mm H 1067mm W x 743mm H 974mm W x 681mm H x 291mm D HF1500CBI 1372mm W x 445mm H 1524mm W x 743mm H 1431mm W x 681mm H x 291mm D Width varies see chart below 743mm all models ...

Страница 6: ...n AC 220V 50Hz 4W CCW 15 18 r min Shipping Size 1562x314x787mm 1105x314x787mm 953x314x787mm UNPACKING AND TESTING Carefully remove unit from box Prior to per manently installing unit test to make sure unit operates properly To do this plug unit s power supply cord into a conveniently located 220 volt grounded outlet CAUTION The unit s power supply cord must be connected to a properly grounded and ...

Страница 7: ...n that is not suscep tible to moisture and is a safe distance from drapes furniture and high traffic areas A qualified electrician should add an electrical outlet per local building codes See shaded area on recessed installation diagram for proper outlet placement Fireplace must be installed to a plumb vertical wall for cor rect operation of touch controls Note Follow all national and local electr...

Страница 8: ...a solid backing Fireplace will stand proud of the finished wall opening by 10mm This is a semi permanent installation Remove screws to relocate 4 Connect the fire feature to the inside of the fire unit 5 Hang the glass face on the fire unit Make certain that the hooks from the on the backside of the glass face are secured in all 4 slots on the fire unit 6 Install the grid in to the glass face Powe...

Страница 9: ...n to turn the machine on This will be indicated by 1 orange LED light The Heat button can be pressed multiple times and will turn on low high and off in that order The Backlight button turns on high medium low and off in that or der Power Heat Backlight When the switch turns on this orange pilot lamp is always on It shows the fire is ener gized The status light above shows that the power is on and...

Страница 10: ...ROL IR RECEIVER MF12VT1 TRANSFORMER MFHF12015 HEATER FAN 220 V 1 5kW MFPHF HF HEATER 220 V 1 5kW MFSM120 SPINDLE MOTOR 220 V 50 60 HZ MFPHF36 LED LED LIGHT STRING HF900CBI MFPHF42 LED LED LIGHT STRING HF1200CBI MFPHF60 LED LED LIGHT STRING HF1500CBI MF PS1 POWER SWITCH MFR1 REMOTE CONTROL HFGLS36 GLASS FACE HF900CBI HFGLS42 GLASS FACE HF1200CBI HFGLS60 GLASS FACE HF1500CBI ...

Страница 11: ...n will be able to adjust the touch screen sensi tivity Q Can the fireplace be installed outside A No Please review the entire safety chapter before installing this fireplace Q Does the fireplace need to be on a dedicated 15 amp circuit A Yes Q What thickness of sheetrock should be used for the recessed installation A 12mm or 16mm Q How often do the batteries in the remote need to be replaced A Ann...

Страница 12: ...rrectly on pins B Fireplace was installed with the power in on position B Turn main power switch to the off position for 30 seconds Switch the fireplace back into the on position for 20 seconds for complete reboot of touch control C Not operating touch control properly with finger C Press flat part of finger firmly on the touch screen and apply moderate pressure D Loose connection on motherboard D...

Страница 13: ...ve B Replace motor CLEANING AND MAINTENANCE INSTRUCTIONS There is very little maintenance involved with your electric fireplace Please follow the few points be low On a semi annual basis unplug the machine from it s power source and wait for the heating ele ment to cool dust the fire unit and glass face with a dry cloth Be careful not to brush any wires that may be exposed as you do this To clean ...

Страница 14: ...14 MAINTENANCE NOTES ...

Страница 15: ...15 MAINTENANCE NOTES ...

Страница 16: ...16 2012 www modernflames com Please dispose of properly ...

Отзывы: