background image

14  

 

CLEANING AND MAINTENANCE INSTRUCTIONS 

There is very little maintenance involved with your electric fireplace. Please follow the few points be-
low: 
 

 

On a semi-annual basis unplug the machine from it’s power source, wait for the heating element 
to cool and dust the fire unit with a dry cloth. Be careful not to brush any wires that may be ex-
posed as you do this. 

 

To clean the glass face of the fireplace simply use your desired glass cleaner with paper towels. 

 

To clean the air inlets/outlets, wipe with a soft cloth or the nozzle of a vacuum cleaner 

 

Dust can easily build up around the heater area under the appliance. Take particular care to 
clean this area on a regular basis to prevent buildup. 

 

If long time no use, please unplug the fireplace and stock it at indoor dry position. 

PROBLEM 

POSSIBLE CAUSE 

CORRECTIVE ACTION 

Flame is not visible when 
unit is turned on  

A. Wiring is loose 

A. Disconnect unit from power 
source and inspect for loose 
connections 

B. Motherboard is defective 

B. Replace motherboard 

Fireplace lights up but 
there is no flame image 

A. Wiring for motor is loose 

A. Disconnect unit from power 
source and inspect for loose 
connections from motor 

B. Motor is defective 

B. Replace motor 

Fireplace is squeaking 
when flame image is on 

 

A. Fireplace spindle/ rod is 
contacting to metal 

A. Apply lithium grease or any 
standard grease to contacts with rod 
and metal 

B. Motor is defective 

B. Replace motor 

A. Wiring is loose 

A. Disconnect unit from power 
source and inspect for loose 
connections 

Heater does not provide 
heat when on 

B. Thermal snap disc has been 
tripped 

B. Turn unit off and unplug unit for 5 
minutes. Plug back in and turn unit 
on. If plug cannot be reached, reset 
breaker and turn unit back on 

C. Heater core is defective 

C. Replace Heater Core 

MAINTENANCE 

MAINTENANCE 

Содержание AL CLX 1500

Страница 1: ...Ambiance CLX Electric Series AL1000CLX AL1500CLX AL2000CLX AL2500CLX AL3600CLX INSTALLATION SERVICE INSTRUCTIONS FOR USE IN UNITED STATES AND CANDA ...

Страница 2: ...ctric heaters have hot and arcing or sparking parts inside Do not use it in areas where gasoline paint or flammable liquids are or are stored This fireplace meets the construction and safety standards of H U D for application in manufactured homes when installed according to these instructions INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference ...

Страница 3: ...ect heater turn controls to the OFF before removing plug from outlet 11 Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire or damage the heater WARNING Improper installation adjust ment alteration service or maintenance can cause injury or property damage Refer to this manual For assistance or additional information consul...

Страница 4: ... not let children play with the appliance unsupervised 24 Heater must not be located immediately below a socket outlet 25 The appliance is not to be used by children or persons with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision and instruction 26 If the supply cord is damaged it must be replaced by the manufacturer its s...

Страница 5: ...s AL1000CLX 559mm W x 254mm H 1016mm W x 648mm H 616mm W x 489mm H x 140mm D AL1500CLX 1067mm W x 254mm H 1524mm W x 648mm H 1124mm W x 489mm H x 140mm D AL2000CLX 1575mm W x 254mm H 2032mm W x 648mm H 1632mm W x 489mm H x 140mm D AL2500CLX 2083mm W x 254mm H 2540mm W x 648mm H 2140mm W x 489mm H x 140mm D AL3600CLX 3200mm W x 254mm H 3658mm W x 648mm H 3258mm W x 489mm H x 140mm D Width varies se...

Страница 6: ...thorized service facility for examination electrical or mechanical ad justment or repair LISTING APPROVALS AL 2500 CLX AL 1500 CLX AL 1000 CLX AL 2000 CLX AL 3600 CLX Volts HZ Amps AC 220V 50Hz 15 Amps AC 220V 50Hz 15 Amps AC 220V 50Hz 15 Amps AC 220V 50Hz 15 Amps AC 220V 50Hz 15 Amps Heater AC 220V 50Hz 1 5kW AC 220V 50Hz 1 5kW AC 220V 50Hz 1 5kW AC 220V 50Hz 1 5kW AC 220V 50Hz 1 5 kW Lamps LED L...

Страница 7: ...tion that is not suscep tible to moisture and is a safe distance from drapes furniture and high traffic areas A qualified electrician should add an electrical outlet per local building codes See shaded area on recessed installation diagram for proper outlet placement Fireplace must be installed to a plumb vertical wall for cor rect operation of touch controls Note Follow all national and local ele...

Страница 8: ...ews are driven in to a solid backing AL1000CLX 635mm W x 502mm H x 100mm D AL1500CLX 1143mm W x 502mm H x 100mm D AL2000CLX 1651mm W x 502mm H x 100mm D AL2500CLX 2159 mm W x 502 mm H x 100 mm D AL3600CLX 3277mm W x 502mm H x 100mm D 2 Attach L metal brackets to the fire unit with he provided small washer head screws Fireplace will stand proud of the finished wall opening by 29mm this area must no...

Страница 9: ...it on the mounting bracket by slotting the key hole slots on the fire unit over the hooks on the mounting bracket 4 Use the included L metal bracket to secure the bottom of the fire unit to the wall This is a semi permanent installation Remove screws to relocate AL1000CLX 450mm AL1500CLX 756mm AL2000CLX 1264mm AL2500CLX 1753mm AL3600CLX 2870mm Use the chart below to see proper distance between the...

Страница 10: ...on to turn the machine on This will be indicated by 1 orange LED light The Heat button can be pressed multiple times and will turn on low high and off in that order The Backlight button turns on high medium low and off in that or der Power Heat Backlight When the switch turns on this orange pilot lamp is always on It shows the fire is ener gized The status light above shows that the power is on an...

Страница 11: ...1 TRANSFORMER 1 AMP MF12VT3 TRANSFORMER 3 AMP MFHF12015 HEATER FAN 220 V 1 5kW MFPHFAL40 MFPHFAL60 MFPHFAL80 MFPHFAL100 MFPHFAL144 HEATER 220 V 1 5kW MFSM120 SPINDLE MOTOR 220 V 50 60 HZ MFP40 LED LED LIGHT STRING AL1000 MFP60 LED LED LIGHT STRING AL1500 MFP80 LED LED LIGHT STRING AL2000 MFP100 LED LED LIGHT STRING AL2500 MFP144 LED LED LIGHT STRING AL3600 MF PS1 POWER SWITCH MFR1 REMOTE CONTROL ...

Страница 12: ...y by the factory Not just any technician will be able to adjust the touch screen sensi tivity Q Can the fireplace be installed outside A No Please review the entire safety chapter before installing this fireplace Q Does the fireplace need to be on a dedicated 15 amp circuit A Yes Q What thickness of sheetrock should be used for the recessed installation A 12mm or 16mm Q How often do the batteries ...

Страница 13: ...eated correctly on pins B Fireplace was installed with the power in on position B Turn main power switch to the off position for 30 seconds Switch the fireplace back into the on position for 20 seconds for complete reboot of touch control C Not operating touch control properly with finger C Press flat part of finger firmly on the touch screen and apply moderate pressure D Loose connection on mothe...

Страница 14: ...BLEM POSSIBLE CAUSE CORRECTIVE ACTION Flame is not visible when unit is turned on A Wiring is loose A Disconnect unit from power source and inspect for loose connections B Motherboard is defective B Replace motherboard Fireplace lights up but there is no flame image A Wiring for motor is loose A Disconnect unit from power source and inspect for loose connections from motor B Motor is defective B R...

Страница 15: ...15 MAINTENANCE WIRING DIAGRAM NOTES ...

Страница 16: ...16 2012 www modernflames com Please dispose of properly ...

Отзывы: