Biomaster Boiler 15-30 Instruction Manual
15
Valve’s probe should be connected to screw-in stub G 1/2 " in case of boiler
equipped with BVTS valve (17, Fig. 1.4.2).
Proposed by the manufacturer thermal protection with coil and
thermostatic valve is efficient only when there is provided pressure of
min. 2.3 bar in the water supply network and safety valve is installed.
Safety valve should be mounted in such a way as to eliminate the risk
of being burned by hot water (3, Fig.1.4.2). Draining stub should be
directed into, e.g. wall, or install outlet pipe into drain.
It means the system may not work when using water drawn from an own well (e.g.
lack of electricity prevents launching of a hydrophore), or in places with frequent
breaks in the supply of water. In this case the boiler should not be installed in sealed
system.
Controller of the device contains protection which shuts down the running of the
boiler at the temperature of 95
ºC.
Installation of the boiler without reliable device draining an excess
of thermal input is forbidden!
Base and the most important element providing safe work of electric
devices
controlling boiler’s work is connecting it to the electrical
installation, conducted according to the requirements and regulations
for boiler rooms.
Electrical installation must be conducted by a qualified person.
a.
b.
Figure 2.6.4. Thermostatic safety valves a) JBV1, b) BVTS
Содержание Biomaster 15