NATURAL GAS CONVERSION INSTRUCTION
11
Locate the new NG valve, verify it is the correct one, the lable
“
NATURAL GAS VALVE ”
should be on the new NG valve.
Attach NG hose to the NG Valve.(see D)
Re-attach bellows to the NG Valve.(see E)
Re-attach thermocouple to the NG Valve.(see F)
Gas inlet
Gas outlet
Please note that the valve has an air inlet and an air outlet with arrows
indicating the flow direction of the gas,
the gas comes out of from the
Natural Gas Piping Quick Disconnect and NG Hose Valve
Orifice Spud Burner.
Failure to follow the instructions could result in fire or explosion,
which could cause property damage, personal injury, or death.
IMPORTANT
!
Connect
Connect
Natural Gas Hose
Quick Disconnect
NG Valve
Burner
NG Orifice Spud
Bellows
NATURAL GAS VALVE
VANNE A GAZ NATUREL
Gas inlet
(bellows connect to
NG source)
Gas outlet
(bellows connect to
burner)
D
E
F
Connect
When connecting the bellows, please ONLY
turn the brass joint counterclockwise on the
bellows.Do not rotate the stainless steel tube.
Excessive rotation of the stainless steel tube
will cause the gas pipe to twist or break,
causing gas leaks.
!
WARNING
Brass joint
SS tube
Brass joint
9 / 40
Natural Gas
Hose