Instruction notice (EN)
20
NOT-MC89-EN-2019-v01
9. Maintenance and Servicing
Take the machine to a registered
modec
distributor for servicing every 400 hours or at least once a month.
Maintenance operation
Weekly
Yearly or as needed
Check and service the actuator by a registered
modec
distributor
Replace the Revolution counter battery *
Check the torque limiter* by a registered
modec
distributor
*The revolution counter is an option
Maintenance to be carried out at the indicated intervals in months or in hours of
use, from the first deadline onwards.
Interval
After each
time used
Every 3 months
or 25 hours
Every 6 months
or 50 hours
Every year or
100 hours
Range
Parts
Task
MC89
Condition of the tool and protective elements
Check
U
MC89
Functioning of the triggers and Stop/ Start button
Check
U
MC89
Functioning of the setting systems for the torque,
speed and direction inversion
Check
U
MC89
Condition of the cables and/or leads
Check
U
U : user – M :
modec
registered distributor / repairer
General recommendations
Take note of all the work health and safety regulatory provisions that apply and any local workplace safety instructions including
conditions relating to the work environment, clothing and the operator’s individual protective equipment as required by all the
applicable regulations.
It is advisable to keep a maintenance log for all maintenance tasks carried out on the actuator.
Prevent foreign bodies from entering the system by using a clean work surface in order to protect the delicate moving parts from
being contaminated by dirt or foreign materials when assembling and dissembling, as this could cause a deterioration of the
mechanical parts.
Maintenance of the Portable Valve Actuators should be carried out by people who have been trained by
modec
.
Our “After Sales Service” department are ready to help in this respect.
Systematically disconnect the actuator from the power feed (battery pack or mains) before carrying out any procedure that
involves replacing, adjusting, servicing or dissembling the actuator or any of its parts.
Every time maintenance is carried out, test the actuator afterwards to check it is working correctly.
Only use approved replacement parts and follow the manufacturer’s advice with regard to lubrication and water-proofing.