Initial Operation of the MX-Proximity-Box
1. Open the MOBOTIX camera's user interface in
the browser
• Enter the IP address of the camera that is con-
nected to the MX-Proximity-Box in the browser
(admin access rights required):
http://<IP address of camera>
2. Activate MxBus interface and MX-Proximity-Box
• Open the
Admin Menu > Hardware Configura-
tion > Manage MxBus Modules dialog.
• Make sure that the
MxBus Interface is connected.
If the interface is not connected, click on
Connect.
• In the
Device section, check if the MX-Proximity-Box
line is set to
Active. If this is not the case, click
on
Refresh.
3. Configure MX-Proximity-Box
• In the same dialog as in step 2, click on
MxMessageSystem Configuration.
• Click on
Load configuration of connected devices.
• Click on
Edit Messages, then on New message
and enter a suitable
Message name.
• Click on the bar with the desired MX-Proximity-Box,
then on
Add.
• Select the
Message name. The Recurrence time
specifies the time to pause before the message
can be sent again.
• In addition, you can select a movement profile for
triggering events. The predefined
Approaching,
Leaving and Movement profiles combine the
corresponding parameters. The
Custom profile
allows setting individual values for special purposes.
• In order to store the MX-Proximity-Box configu-
ration, click on
Transfer entire configuration.
4. Configure events
• Open the
Setup Menu > Event Control > Event
Overview dialog.
• In the
Message Events section, click on Edit and
create the profiles for message events as required
(e.g., for starting a recording).
5. Store the camera configuration
• In the Live screen of the camera, click on
Admin
Menu > Configuration > Store, permanently store
the camera configuration and reboot the camera.
Safety Warnings
• This product must not be used in locations exposed
to the dangers of explosion.
• Make sure that you install this product as outlined
in the installation instructions above.
• The MOBOTIX MX-Proximity-Box is to be used only
for detecting movements using radar sensors in IP66
environments.
• Electrical systems and equipment may only be
installed, modified and maintained by a qualified
electrician or under the direction and supervision of
a qualified electrician in accordance with the appli-
cable electrical guidelines. Make sure to properly set
up all electrical connections.
• Make sure that you adhere to all relevant laws, regula-
tions and that you fulfill all certification requirements
for the intended use.
• Torque for all screws: 0.4 Nm.
• Press the white cable plug (eight-wire plug or cable
plug 3 to 5 mm or 5 to 7 mm) into the casing in such
a way that the rims stick out equally on both sides.
• Make sure to use only twisted-pair cabling (e.g.,
J-Y(St)Y) for MxBus wiring.
• The length of the entire MxBus wiring must not exceed
100 m/328 ft.
• Diameter of all wires: 0.6–0.8 mm (0.8 mm = AWG 21
recommended to reduce line losses).
Technical Specifications
MX-Proximity-Box
Connection
MxBus (2 terminals)
Power Supply
48 V DC (via camera and MxBus)
Power consumption
0.5 to 1 W
Frequency (radar signal)
~24 GHz
Operating Conditions
IP66 (DIN EN 60529)
–20 to +60 °C/–4 to +140 °F
Dimensions (height x width x
depth)
63 x 87 x 30 mm/2.48 x 3.43 x 1.18 in
Materials
Housing: PBT GF30
Weight
Approx. 75 g/0.17 lb
Detection area
Persons: 0 to max. 15 m/16.40 yd; cars: 0 to max. 35 m/38.28 yd
Concealed installation
Possible behind materials with low absorbability of radar waves
(e.g.,
uncoated glass, plastics, various wood-based materials , drywall
).
It is highly recommended to test the material before installing!
Further Information regarding
detection
Detectable movements: Approaching, leaving and general motion
detection
Drilling Template
75 mm/2.95 in
MX-Proximity-Box
Drilling t
emplat
es f
or other MOBO
TIX c
omponents:
www
.mobotix.
com
> Support
> Manuals
Resetting the MX-Proximity-Box
If the MX-Proximity-Box had been connected to a
different camera before and was not deactivated or
reset before detaching, the left LED (operating status)
may flash red after establishing the connection. In this
case, you need to reset the connected and activated
MX-Proximity-Box to
factory defaults:
• Remove the box cover.
• Bridge the contact surfaces in the bottom right
corner (red circle in figure) using a screwdriver,
for example (both LEDs are flashing red/blue with
increasing frequency).
• Only remove the bridge if both LEDs of the
MX-Proximity-Box are flashing green on/off 3
times to indicate that the process has finished
successfully.
• Mount the cover back onto the box.
• Set up the MX-Proximity-Box in the camera (see
«Initial Operation of the MX-Proximity-Box»).
This device is granted pursuant to the Japanese Radio Law (
電波法
)
This device should not be modified (otherwise the granted designation number will become invalid)