background image

www

.mobotix.com

Innovations – Made in Germany

The German company MOBOTIX AG is known as the leading pioneer in network camera technology and its decen-
tralized concept has made high-resolution video systems cost-efficient.

MOBOTIX AG • D-67722 Langmeil • Phone: +49 6302 9816-103 • Fax: +49 6302 9816-190 • [email protected] 

Security-Vision-Systems

EN

Quick Install

MX-BPA-Box

Copyright © MOBOTIX AG 2015 • Made in Ger

many • T

echnical infor

mation subject to change without notice.

  

 2015 • Declaration of Confor

mity: twww

.mobotix.com > Support > Media Library > Certi

ficates

Drilling Template

80 mm/3.15 in

80 mm/3.15 in

75 mm/2.95 in

15 

mm/

 

0.59 in

MX-BPA-Box

M15D/M25M Wall Mount

Drilling templates for other MOBOTIX wall mounts:

www

.mobotix.com > Support > Manuals

Safety Warnings

•  This product must not be used in locations 

exposed to the dangers of explosion.

•  Make sure that you install this product as outlined 

in the installation instructions above.

•  The MOBOTIX MX-BPA-Box is to be used only 

as additional power supply for MOBOTIX MxBus 
modules in IP65 environments.

•  For MOBOTIX cameras with MxBus connector.
•  One MX-BPA-Box must not be connected to 

more than one camera (MxBus master)!

•  Make sure that only one MX-BPA-Box is con-

nected to one MxBus! 

•  Torque for all screws: 0.4 Nm.
•  Electrical systems and equipment may only be 

installed, modified and maintained by a qualified 
electrician or under the direction and supervision 

of a qualified electrician in accordance with 
the applicable electrical guidelines. Make sure 
to properly set up all electrical connections.

•  Make sure that you adhere to all relevant laws, 

regulations and that you fulfill all certification 
requirements for the intended use.

•  Press the white cable plug (eight-wire plug or 

cable plug 3–5 mm or 5–7 mm) into the casing 
in such a way that the rims stick out equally 
on both sides.

•  Make sure to use only shielded twisted-pair 

cabling (e.g., 

J-Y(St)Y

) for MxBus wiring.

•  The length of the entire MxBus wiring must not 

exceed  100 m/110 yd.

•  Diameter of all wires: 0.6–0.8 mm (0.8 mm = 

AWG 21 recommended to reduce line losses).

LED Signaling

Device Status

LED off
LED permanently on

LED

Meaning

Device 

Status

Regular operation

Error, e.g., input voltage 

below 12 V

Technical Specifications

MX-BPA-Box

Connection

MxBus (2 x 2 terminal connectors)

Power Supply

External power supply 12–48 V DC

Power Consumption

0.5–11.5 W

Output Rating

Power supply with 12–23.9 V:

 

6 W

Power supply with 24–48 V:

 

9 W

Operating Conditions

IP65 (DIN EN 60529) 

–30 to +60 °C/–22 to +140 °F (DIN EN 50155)

Dimensions (height x width x depth)

63 x 87 x 30 mm/2.48 x 3.43 x 1.18 in

Materials

Housing: PBT GF30

Weight

Approx.  75 g

Отзывы: