INSTALLING TITAN ON A VEHICLE 

  

2 TYPES OF INSTALLATION

 

1.

 

BASIC INSTALLATION: requires installation of cables:  

a.

 

RED: positive 

b.

 

BLUE: ground 

c.

 

YELLOW: key / dashboard  

2.

 

ADVANCED INSTALLATION: installation of optional accessories or other available outputs and inputs 

 

CONNECTING THE CABLES 

 

The cables must be connected while TITAN is not powered on 

 

The cables should be secured to other cables or parts not subject to movements. Try to avoid proximity to heat sources 
and moving objects near the wires 

 

The connections must not be visible. If the factory insulation has been removed, restore the cable insulation 

 

Additional insulation must be applied if the cables are installed outdoors or in places where they can be damaged or 
exposed to heat, moisture, dirt, etc. 

 

Cables cannot be connected to on-board computers or control units 

 

POWER SUPPLY (red cable: positive) 

 

Make  sure  that  after  turning  off  the  vehicle's  on-board  computer,  there  is  still  power  available.  Depending  on  the 
vehicle, this can occur within a time of 5/30 minutes 

 

When  TITAN  is  connected,  be  sure  to  measure  the  voltage  to  verify  that  it  has  not   
decreased 

 

It is advisable to connect the main power cable in the fuse box 

 

CONNECTING THE IGNITION CABLE (yellow cable: DIN1) 

 

Check to make sure it's an actual ignition cable: the power should not cut off while the vehicle engine is running; the 
power should cut off when the vehicle and dashboard are turned off 

 

Check to make sure it isn't an ACC cable (when the key is in the first position, the majority of the vehicle's electronic 
utilities should be available) 

 

Check that power is still available when other devices on the vehicle are turned off 

 

Check that the ignition is connected to the power relay output. As an alternative, any other relay that has output power is 
fine (when the vehicle is turned on) 

 

 GROUND CONNECTION (blue wire: ground) 

 

The ground wire must be connected to the vehicle's chassis or metal parts that are fixed to the body 

 

If the ground wire is secured with a bolt, the loop must be connected to the wire 

 

For the best contact point, remove any paint stains from the spot at which the loop is connected 

 

Caution: The mains connection must be at a very low impedance point in the vehicle's electrical system. On a car, 
these points are the battery terminals. Therefore, it is advisable to connect the power supply for TITAN (GND and 
POWER cable) directly to the battery terminals.  
 

Another option is to connect the power supply inside the fuse box (if this is not possible, connect to the power supplied to the 
point at which the on-board computer fuses are located).  
 
Connecting the ground wire at an arbitrary point to the mass of the vehicle is unacceptable, because the potential static and 
dynamic on the ground line will be unpredictable, and may cause unstable operation and damage TITAN. 

 

Содержание TITAN

Страница 1: ...ECTION AND TRACKING SYSTEMS THANK YOU FOR CHOOSING MOBISAT TITAN THIS MANUAL OUTLINES IN DETAIL ALL THE SERVICES OFFERED BY THE PRODUCT FOR THE PRODUCT S PROPER USE WE RECOMMEND READING THE ENTIRE MANUAL THOROUGHLY TITAN User manual V2 0 3 ...

Страница 2: ... We recommend these instructions be carefully followed to avoid any hazardous situations TITAN uses a 10V 30V DC power supply The nominal voltage is 12V DC To avoid mechanical damage we recommend carrying TITAN in a shockproof container pack Before using TITAN set the device so as to be able to comfortably view the LED indicators which show the device s operating status Disconnect the vehicle s ap...

Страница 3: ...d box containing all accessories necessary for its use The package contains Device TITAN Short guide MAIN SPECIFICATIONS Satellite protection is always on the alarm is activated automatically with the removal of the key or an iButton Satellite tracking in real time on a mobile telephone and Mobisat Greenbox service Accuracy 2 metres Deep Sleep mode energy saving Virtual odometer GNSS measures the ...

Страница 4: ...rocessor M3 Internal GSM and GNSS antennas integrated Integrated backup battery 3 Digital Inputs 1 Analog Input 2 Digital Outputs 1 Dallas Connection Wire iButton Measurements 66 5x49 7x24 2mm NAMES OF PARTS PHYSICAL SPECIFICATIONS Navigation LED LED Modem LED LED USB Mini USB input TECHNICAL DETAILS Power supply 10 30V DC 2W Max Consumption GPRS 88 mA rms 462 mA Max Nominal Average 50 mA rms GPS ...

Страница 5: ...Ohm Input Voltage recommended operating conditions 0 Supply Voltage V Input voltage threshold DIN1 7 5 V Input voltage threshold DIN2 DIN3 2 5 V Analog Inputs Input Voltage recommended operating conditions Range 1 0 10 V Input Resistance Range 1 120 kOhm Input Voltage recommended operating conditions Range 2 0 30 V Input Resistance Range 1 146 7 kOhm MAXIMUM RATINGS DESCRIPTION Min Type Max Unit S...

Страница 6: ...osition from the GPS tracker Although sending 1 position has a weight of just a few bytes the operator charges for 1Kb for each connection similar to a flat fee per answered call Therefore 1 position 1Kb The product s consumption of data traffic depends on its configuration and the average number of hours a vehicle is in motion TITAN can be configured to send more data when it is moving and less d...

Страница 7: ...THE SIM CARD 1 Open TITAN s outer casing using a screwdriver 2 Lift the cover to reveal the slot in which to insert the SIM card 3 Insert the SIM card by sliding it into the slot as indicated 4 Close TITAN s outer casing by correctly pressing together the two parts as shown 5 TITAN is now ready for use ...

Страница 8: ...ickly and constantly Start Mode Off The device is not working The device firmware is corrupt MAIN CABLE CONNECTION Pin No Colour Behaviour Meaning 1 Red VCC 10 30 V DC Module power supply Power supply range 10 30 V DC 2 Pink OUT2 Digital Output Channel 2 Output collector open Max 300mA 3 White OUT1 Digital Output Channel 1 Output collector open Max 300mA 4 Grey DIN2 Digital Input Channel 2 5 Yello...

Страница 9: ...n cable the power should not cut off while the vehicle engine is running the power should cut off when the vehicle and dashboard are turned off Check to make sure it isn t an ACC cable when the key is in the first position the majority of the vehicle s electronic utilities should be available Check that power is still available when other devices on the vehicle are turned off Check that the igniti...

Страница 10: ...es such as iButton door sensors panic buttons etc must be purchased separately INSTALLING AN iButton iButtons are unique recognition devices since each has its very own unique alphanumeric identification code TITAN is able to read these devices thanks to its Dallas WIRE connection iButtons can be used for Driver recognition TITAN is capable of storing up to 50 iButton codes In this mode the vehicl...

Страница 11: ... of a Panic Button open door sensor etc If the sensor s output signal is negative a relay must be installed to convert the negative signal to positive as shown below RELAY AND STARTER BLOCK IMMOBILIZER The connection below shows the vehicle s start relay wiring diagram TITAN can disable the starter when the output is in OFF If an iButton is installed the Immobilizer controls the device s output 2 ...

Страница 12: ...01 For Telecom Italia Mobile the Home Operator is 22201 An updated list of these codes can be found on the website http mcclist com COMMAND SMS TEXT ENABLE GPRS CONNECTION space space setparam space 1240 space 1 APN CODE space space setparam space 1242 space apn code APN user name if necessary space space setparam space 1243 space apn username APN password if necessary space space setparam space 1...

Страница 13: ... scenario DIN1 must be installed in order for the Immobilizer to function correctly DOUT2 is always OFF The status changes to ON when the vehicle is started DIN1 1 When any iButton code is read from the device the DOUT2 status switches to OFF After identifying the iButton DIN1 will switch to OFF making it possible to start the vehicle for 30 seconds after which the iButton must be identified once ...

Страница 14: ...CING CONTROLS TITAN sends each alarm to the Mobisat Greenbox service and your Smartphone via a push notification if the Greenbox APP is installed on the Smartphone and if push notifications are enabled It is advisable to configure the product to also send 1 SMS in case of theft in the event that the Internet connection on your Smartphone is not active A mobile phone number at which to send the the...

Страница 15: ...ssist in real time with any action by any vehicle in your fleet from one to a virtually infinite number of vehicles TO ACCESS THE SERVICE To connect TITAN to the Greenbox service you must register the device using the two codes found on the product s packaging the IMEI no the activation code Serial no TROUBLESHOOTING TITAN will not start up Check that the power cables are properly connected The SI...

Страница 16: ...afety regulations is prevented Do not try to open the product If the product has suffered damage or power cords were not insulated do not touch the product and immediately consult a qualified professional Do not leave the unit connected to a power source when not in use Do not use extension cords or other accessories other than those expressly recommended by the manufacturer to avoid risk of fire ...

Отзывы: