background image

Zeus150 

                                                           User Manual 

V 1.1.5 - 21/10/2020 

          Page 6 of 16 

2.1  Main Menu - Home 

The Home Menu is shown in the following picture.  

 

 
 

 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
This menu shows the status of the system in terms of energy management. It clearly indicates 
which  energy  source  is  charging  which  type  of  battery.  It  shows  the  actual  mode  of  operation 
(manual or automatic) the charge level of the batteries, the status of the timers, the activation or 
not of the

 

"High-Mountain" function and the possible forced recharging for the engine battery. 

 
General notes: 

  The Mode can have three settings: 

o

 

: optimizes the operation keeping the background noise low  

o

 

: optimizes the production of electricity, consumption and noise 

o

 

: for maximum electricity production 

Note

: Full-Eco and Eco-Silent steps may take a few minutes, due to the need to dissipate 

excess  heat  compared  to  the  mode  chosen.  It  is  therefore  recommended  to  select  the 
desired mode within the first 5 minutes after switching on. on. 

  The operating mode icon can have the following forms: 

  

o

 

           

Automatic mode; the icon flashes when the generator is working 

o

            Manual mode; generator active  

o

            Manual mode; generator not active  

  The solar panel icon will be on only if the solar panel is charging 

  The  blue  arrows  with  a  continuous  line  indicate  which  of  the  energy  sources  is  in 

operation and which of the batteries is being charged 

  For both batteries the percentage of remaining charge is displayed 

  Timer  icons  are  displayed  only  if  the  related  timers  have  been  set.  Available  only  in 

automatic mode, the icons can have the following colors: 

o

  Blue: timer set and active

 

o

  White: timer set but not active 

Automatic/Manuale 

mode 

  

 

Solar 
panel 

management 

  

 

Thermoelectric 

generator 

management 

termoelettrico 

are 

  

 

Primary 
battery 

management 

  

 

Engine 

battery 

management 

  

 

Setup Menu 

  

 

Timer2 

  

 

Timer1 

  

 

Battery 

actually 

charged 

  

 

Active energy 

source 

  

 

Engine 

battery 
forcing 

  

 

Eco/Full/Silent 

Mode 

  

 

Содержание ZEUS150

Страница 1: ...or USER MANUAL ZEUS150 CD Power Supply Diesel IMPORTANT You can obtain the 3 three year warranty extension by registering the product for free on shop mobiltech it More information can be found in cha...

Страница 2: ...have a system capable of charging the batteries of your vehicle regardless of the availability of external electricity or weather conditions Installation and commissioning must be performed by specia...

Страница 3: ...TENTION NEVER disconnect for any reason the primary battery when the generator is working The operation is very harmful because the cooling of the device will be lost causing possible breakages due to...

Страница 4: ...s components Do not wash the generator using a pressure washer The generator is not designed to work submerged in water or other liquids in the event of flooding the warranty becomes void and it is ne...

Страница 5: ...w the menu structure is shown HOME SETTINGS TIMER MODE LANGUAGE SERVICE GENERATOR CONTROL UNIT Timer 1 Timer 2 Clock Automatic Manual Battery automatic selection Engine battery forcing Italian English...

Страница 6: ...t is therefore recommended to select the desired mode within the first 5 minutes after switching on on The operating mode icon can have the following forms o Automatic mode the icon flashes when the g...

Страница 7: ...ntly both graphically and numerically 2 1 2 Thermoelectric generator management Pressing the generator icon the screen display the Menu related to the energy supplied by the thermoelectric generator T...

Страница 8: ...menu is shown The battery data is displayed on the left Type Actual voltage The percentage of engine battery charge is displayed on the right side of the screen Battery data Percentage of charge Perc...

Страница 9: ...wo available Timers as well as the internal clock To set a timer press the related time and make the desired adjustments in the central part of the screen When the two timers are activated the related...

Страница 10: ...e primary battery services with respect to the engine battery Nevertheless the latter is constantly monitored and if its voltage falls below a minimum value it will be immediately charged Battery Engi...

Страница 11: ...ers Software update The two icons at the bottom right display the status of communications between the different components of the system C communication between the display unit and the power unit G...

Страница 12: ...tatus of the generator components The icons shown in this figure can have on three different colors Blue working element actually active Gray working element actually not active Red failed element err...

Страница 13: ...splay shows Service batt low Low voltage of service battery Power on the generator Display shows Service batt overtempt Service battery temperature too high Place the service battery in a more ventila...

Страница 14: ...erification Display shows Water overtemperature Coolant temperature too high Wait for the coolant temperature to drop Display shows Water outlet probe error Fault or lack of connection with outlet wat...

Страница 15: ...ion R10 rev 5 A1 EN61000 6 1 2007 EN61000 6 3 2007 A1 2011 Standard ENV Cold A EN60068 2 1 15oC Standard acoustic tests EN ISO 3744 Power supplied 150 Wh typical see graphic below Note how the product...

Страница 16: ...ch it Mail info mobiltech it service mobiltech it Date Hours of operation Stamp and Signature Date Hours of operation Stamp and Signature Date Hours of operation Stamp and Signature Date Hours of oper...