Step 4 – RF Service Configuration 

Define the RF parameters by choosing the Service1/Service2 tab in 
the work area: 

 

DL central frequencies for each service according to the  
following ranges.    

 

EGSM: 925 - 960 

 

UMTS: 2110 - 2170 

 

PCS: 1930 - 1990 

 

CELL: 869 - 894 

 

DCS: 1805 - 1880 

 

Max expected power of BTS (0-33dBm) 

 

UL Gain for each service (5 to -15dB) 

 

Step 5 – (Optional) Auxiliary Alarms and Alarm Output Connections 

Connect the Auxiliary Alarms and Alarm Output connections on the 
 Master VCU rear panel Alarm port according to the instructions given 
 in the 

VE Dual-Band Installation and Configuration Guide

 

Step 6 – Connect the Slave VCUs to the Master VCU  

a)

 

Install each Slave VCU in the IDF/Telco closets corresponding to the floors to be covered.  

Note: VAPs for each VCU can be located over more than one (adjacent) floor. 

b)

 

Connect the VCU/VCH port to the patch-panel that feeds the dedicated CAT-6 cabling system for connection 
to the Master VCU (one of the VAP ports). 

 

 

Note: Verify that the VCU/VCH LED completes initialization (blinking light) and shows a solid green light. The RF 
LEDs (of both services) should turn OFF. 

 

QIS_VE Dual Band_Rev A00 709C005002_28JAN10.doc 

 

 

 

 

 

 

 

 

           

 

Содержание MobileAccessVEDual-Band

Страница 1: ...od 4 long screws for securing the wall mount adaptor to the wall for anti theft installation The included power cord should not be used with any products other than the VE Control Unit Required Equipm...

Страница 2: ...by the service provider The passive interface can either be a coaxial cable or include other RF components such as splitters attenuators bi directional couplers etc Up to 12 Slave VCUs are connected...

Страница 3: ...t existing cables support the VE installation If infrastructure documentation is available review the documentation to determine cable types and lengths If the cable information is not available attem...

Страница 4: ...33 feet 10 m from the outer building walls so mobile users have line of sight to VAPs EGSM UMTS or DCS UMTS 45 feet 13 5 m apart Maximum of 22 5 feet 7 m from the outer building walls so mobile users...

Страница 5: ...elect the VCU M Master from the network topology tree and refer to the Module Info sub tab e Click the Modify button to define an indicative name for the VCU up to 17 alpha numeric characters Step 1 I...

Страница 6: ...panel Alarm port according to the instructions given in the VE Dual Band Installation and Configuration Guide Step 6 Connect the Slave VCUs to the Master VCU a Install each Slave VCU in the IDF Telco...

Страница 7: ...tor on the VE Access Pod b Secure the Desk Mount Adaptor to the VAP using 4 short screws c Connect the RJ 45 Cat 5e jumper cable to the VAP s RJ 45 port d Place the VAP in the planned location on a fl...

Страница 8: ...ition to the internal antennas VAPs are equipped with interfaces to external antennas that can be used for special coverage requirements The maximum external antenna gain should not exceed 10 dBi When...

Отзывы: