
System Installation
MA 1000 Installation and Configuration Guide
18
4.2.1
Rack Installation General Instructions
Verify
that the rack height can support all the units to be installed, where you may also want to
consider future expansions.
Figure 13 shows the recommended physical location of the MobileAccess elements in the rack in
order to facilitate and simplify the cabling
connections. The configuration is for a single operator.
If the site is serviced by more than one operator, each operator often installs their equipment in
a separate rack.
NOTE:
Note that the
410, 430 SC-450 controller
is at eye level to provide an easy view of the
LED indicators and LCD display and easy access to the local and remote monitoring connections.
Figure 13: Recommended Order in the Communication Room Rack
MobileAccess Controller (1U)
MobileAccess RIU (3U)
MobileAccess
Power Supply (3U)
Fiber Optic Patch Panel
and Tray
(variable size)
At eye level
MobileAccess Base Unit 6 (1U)
MobileAccess Base Unit 1 (1U)
MobileAccess Base Unit 2 (1U)