MobileAccess
1000 System with
LTE SISO Support
Installation and Configuration Guide
P/N: 709C00150x
REV: A00
Date: FEB-2010
Страница 1: ...MobileAccess1000 System with LTE SISO Support Installation and Configuration Guide P N 709C00150x REV A00 Date FEB 2010...
Страница 2: ...ORMAT OR MEDIA IN WHOLE OR IN PART WITHOUT THE PRIOR WRITTEN CONSENT OF MOBILEACCESS INFORMATION CONTAINED IN THIS DOCUMENT SUPERSEDES ANY PREVIOUS MANUALS GUIDES SPECIFICATIONS DATA SHEETS OR OTHER I...
Страница 3: ...R REPRESENTATIVES ARE NOT AUTHORIZED TO MAKE COMMITMENTS ON WARRANTY RETURNS Returns IN THE EVENT THAT IT IS NECESSARY TO RETURN ANY PRODUCT AGAINST ABOVE WARRANTY THE FOLLOWING PROCEDURE SHALL BE FOL...
Страница 4: ...O INHERENT SIGNIFICANT RF RADIATION THE RF LEVEL ON THE DOWN LINK IS VERY LOW AT THE REMOTE UNITS RHUS DOWNLINK PORTS THEREFORE THERE IS NO DANGEROUS RF RADIATION WHEN THE ANTENNA IS NOT CONNECTED Las...
Страница 5: ...products have met the approvals of the following certifying organizations Product Certifications US FCC 47 CFR part 15B 22 24 90 27 UL 60950 1 21CFR 1040 10 1040 11 Europe EN 301502 EN 300609 EN 3014...
Страница 6: ...are included in your system installation P N Description 709C001503 1000 Installation and Configuration Guide 709C001205 2000 Installation and Configuration Guide 709C002502 RIU Installation and Confi...
Страница 7: ...Units 9 2 2 1 1 BU Front Panel 10 2 2 1 2 BU Rear Panel 11 3 Site Preparation 12 3 1 Infrastructure Preparation 12 3 2 Installation Requirements 12 3 3 Coaxial Cable Connections 12 3 3 1 General Cable...
Страница 8: ...tallation 20 4 2 5 RIU Connections 21 4 2 6 BU Connections 21 4 2 7 Controller Connections 21 4 3 Remote Site Installation 22 4 3 1 1000 RHU Installation 22 4 3 1 1 Wall Mount 23 4 3 1 2 Connections 2...
Страница 9: ...nsures optimal performance for all services Local and remote end to end monitoring and control through an interface to 410 430 or SC 450 system controller Low power system requirements eliminates the...
Страница 10: ...the following devices Radio Interface Units RIUs The RIUs provide interfaces for up to three BTS BDA signals and automatically adjusts the output signal in response to input signal level in order to p...
Страница 11: ...S 1800 Figure 2 MA 1000 Basic BU RHU Configuration B Using the MobileAccess Add on unit to provide an additional service A Add on unit can be connected to a 1000 or 2000 RHU to provide a third service...
Страница 12: ...ion which communicates via SNMP over a Ethernet TCP IP connection The 430 may also be monitored via a 3rd party SNMP application for receipt of SNMP traps SC 450 enables management of the 1000 2000 sy...
Страница 13: ...site and the supported services The following sections describe each of the system elements NOTE The connections as they relate to the MA 1000 system are described in Chapter 4 System Installation 2 1...
Страница 14: ...nfrastructure through the 1000 RHU antenna ports However if 860 WLAN solution is also installed the combined data and voice services are fed to the coax infrastructure through the 860 antenna ports NO...
Страница 15: ...service which is combined with the RHU services and distributed through the common coax infrastructure DL UL Transmit the RF signals to and from the Add on module These ports are connected to the cor...
Страница 16: ...re 7 RHU Add on Front panels Table 2 3 MobileAccess Add on Front Panel Indicators LED Description RUN When blinking indicates that the RHU is in normal operating mode PWR Power ON 2 1 2 2 Add on Rear...
Страница 17: ...High port 2 2 Base Units The BUs Base Units perform RF to optical conversion of the signal on the BTS BDA side Each can support up to two services provided by the same operator Two models of BUs are...
Страница 18: ...or Link 5 to Link 8 Figure 9 Eight Port BU Front Panel Figure 10 Four Port BU Front Panel Table 2 5 BU Front Panel Indicators LED Description PWR Power input detected for the corresponding unit LSR O...
Страница 19: ...a four port BU one uplink and one downlink port is connected for an eight port BU two uplink and two downlink ports are connected Figure 11 BU Rear Panel RF Connections Table 2 6 BU Rear Panel Connec...
Страница 20: ...to the specific installation 3 3 Coaxial Cable Connections 3 3 1 General Cable Installation Procedures Observe the general cable installation procedures that meet with the building codes in your area...
Страница 21: ...C 1045342 Black Brown boots 1Meter MA 50000105 Diamond p n ENC 1045343 Black Brown boots 3 Meter MA 500001060 Zipcord patchcord 4xSC APC 62 5 125 900 2000 4500 micron Diamond p n ENC 1045344 Beige Bro...
Страница 22: ...ivalent for checking coax cables including the antennas 2 The VSWR must be measured prior to terminating the RHUs in the remote communication rooms Terminate all unused RHU and RIU ports with a 50 ohm...
Страница 23: ...MobileAccess supplies various power supplies that can be installed in a rack or mounted on a wall depending on your configuration 3 5 Installation Conventions Some of the basic installation conventio...
Страница 24: ...the main communication room and individual wire pairs are terminated into the power feed of individual units By providing power from a single distribution point maintenance can be reduced and UPS bac...
Страница 25: ...telecommunication room close to the RF signal source This installation may differ between single and multi building topologies B Remote locations RHU and Add on installations and connections These are...
Страница 26: ...is for a single operator If the site is serviced by more than one operator each operator often installs their equipment in a separate rack NOTE Note that the 410 430 SC 450 controller is at eye level...
Страница 27: ...k and around the installed components so that the safety of the equipment is not compromised It is recommended to allow for at least about 2 cm of airspace between devices in the rack Verify that the...
Страница 28: ...ding 1 installation in a remote location with several Base Units For clarity the example shows two Base Units However the configuration applies to a maximum of four 8 port Base Units that are supporte...
Страница 29: ...e BUs 1 Connect 3 125 900 pigtail with SC APC connectors between splice tray and patch panel cabinet 2 Connect 3 125 3000 SC APC jumpers between the corresponding BU and patch panel 3 Connect the fibe...
Страница 30: ...ation Guide 22 4 3 Remote Site Installation 4 3 1 1000 RHU Installation Mount and install each RHU on the wall in the communication shaft or communication room The following provides the dimensions fo...
Страница 31: ...the rules for handling and connecting F O cables The F O cables will be connected to the associated BU in the communication room at a later phase 1 Connect fiber optic cable to splice box and to SC AP...
Страница 32: ...System Installation MA 1000 Installation and Configuration Guide 24 4 3 2 Add on Installation The following figure provides the dimensions for the Add On unit Figure 18 Add On Dimensions...
Страница 33: ...6 32 NC screws 2 Position the RHU Add on unit on the bracket and secure the Add on to the bracket using the four supplied 8 32 screws 3 Interconnect the 1000 RHU and RHU Add on SMA Uplink Downlink an...
Страница 34: ...s Refer to the corresponding User Manual for detailed instructions on installing the unit 4 3 4 Antenna Connections For systems without the 860 WLAN solution modules connect the antenna connections to...
Страница 35: ...ency Ranges Services Frequency Range Uplink Downlink LTE SISO 698 716 and 777 787MHz 728 757MHz CELL 824 849 869 894 iDEN SMR800 806 824 851 869 GSM 890 915 935 960 SMR900 Paging 896 902 929 941 DCS 1...
Страница 36: ...ain dB 20 7 10 7 20 7 14 7 20 7 10 7 Pin dBm 0 0 0 0 0 0 Input IP3 dBm AGC OFF Min 5 5 5 5 5 5 Input IP3 dBm AGC ON Min 5 5 5 5 5 5 SFDR dB 69 73 68 74 74 68 74 73 Max Intermod Distortion dBm 13 13 36...
Страница 37: ...17 17 4 carriers 10 14 14 8 carriers 7 11 11 12 carriers 5 9 9 Mean Gain dB 16 3 20 3 20 3 Pin dBm 0 0 0 Input IP3 dBm AGC OFF Min 6 6 6 Input IP3 dBm AGC ON Min 3 3 3 SFDR dB 65 67 70 65 Max Intermod...
Страница 38: ...1 3 21 Pin dBm 1 0 1 0 0 Max Intermodulation Distortion dBm 13 13 Input IP3 dBm 7 7 7 7 SFDR dBm 2 66 64 66 55 Max NF dB 18 18 18 18 Gain Flatness dB 3 2 0 1 04 WCDMA compiles with 3GPP TS 25 106 V5 0...
Страница 39: ...3 dB total Max distance 300 m Multi mode Optical loss per mated pair connectors 0 5dB max Optical Connector SC APC Fiber type 9 125 SM 50 125 um or 62 5 125 multimode fiber with the minimum requireme...
Страница 40: ...n to the MA 410 MA 430 or SC 450 controller Physical Dimensions 48 26x4 44x29 97cm 19 x1Ux11 8 Weight 3Kg 6 6 lb Supported services Two services corresponding to the model Power Input power 20 to 48V...