MOBILE-ALERTS MA10006 Скачать руководство пользователя страница 2

 

31

Indoor relative 
humidity in 
RH%

 

Indoor 

temperature 

in ºC

WEATHER TENDENCY INDICATOR 

The weather tendency indicators (located on the left side of the weather icons) are working 
together with the weather icons. When the indicator points upwards, it means that the air-
pressure is increasing and the weather is expected to improve, but when indicator points 
downwards, the air-pressure is dropping and the weather is expected to become worse. 

 

Taking this into account, one can see how the weather has changed and is expected to 
change. For example, if the indicator is pointing downwards together with cloud and sun 
icons, then the last noticeable change in the weather was when it was sunny (the sun icon 
only). Therefore, the next change in the weather will be cloud with rain icons since the 
indicator is pointing downwards. 

 

Note:

 

 

Once the weather tendency indicator has registered a change in air pressure, it will remain 
permanently visualized on the LCD.

 

 

AIR PRESSURE HISTORY (ELECTRONIC BAROMETER WITH BAROMETRIC 
PRESSURE TREND) 

The right side of the second section of the LCD shows the air pressure history bar graph.  
 
 
 
 
 

 
 
 

The bar graph indicates the air pressure history trend over the last 12 hours in 7 intervals: 0h,      
-3h, -6h, -9h and -12h. The “0h” represents the current full hour air pressure recording. The 
columns represent the “hPa” (0, ±1, ±3, ±5) at specific time. The “0” in the middle of this scale 
is equal to the current pressure and each change (±1, ±3, ±5) represents how high or low in 
“hPa“ the past pressure was compared to the current pressure. 
If the bars are rising it means that the weather is getting better due to the increase of air 
pressure. If the bars go down, it means the air pressure has dropped and the weather is 
expected to get worse from the present time “0h“. 

Note: 

 

For accurate barometric pressure trends, the weather station should operate at the 
same altitude for recordings (i.e. it should not be moved from the ground to the second 
floor of the house). When the unit is moved to a new location, discard readings for the 
next 12 hours. 

 

The level of the pressure bar will be affected by the temperature change and it is for 
reference only. 

 

INDOOR TEMPERATURE/HUMIDITY DATA 

The indoor temperature and humidity data are automatically updated and displayed on the 
first section of the LCD.

 

 
 

 

 
 
OUTDOOR TEMPERATURE/HUMIDITY DATA 

The last LCD section shows the outdoor temperature and humidity, and the reception 
indicator.

 

 

 

 
 
 

TOGGLING AND RESETTING THE TEMPERATURE MIN/MAX DATA 

 

TO VIEW THE MIN/MAX TEMPERATURE DATA 

Press the 

MIN/MAX 

key several times to view the MIN/MAX indoor and outdoor temperature 

sequentially.  

 

Note:

 the outdoor MIN/MAX temperature records will also display the recorded time and date.  

 
 
 
 
 
 
 
 
 
 

 

 

 

TO RESET TEMPERATURE MIN/MAX DATA

  

Press and hold 

MIN/MAX

 key for 3 seconds to reset all the indoor and outdoor temperature 

to current temperatures. 

 

ABOUT THE THERMO-HYGRO TRANSMITTER 

The range of the thermo-hygro transmitter may be affected by the temperature. At cold 

temperatures the transmitting distance may be decreased. Please bear this in mind when 

positioning the transmitters. Also the batteries may be reduced in power for the thermo-hygro 

transmitter. 

 

CHECKING FOR 868MHz RECEPTION 

If the outdoor temperature and humidity data are not being received within three minutes after 

setting up (or outdoor display always shows “- -.-” in the outdoor section of the weather 

station during normal operation), please check the following points: 

1. 

The distance of the weather station or transmitters should be at least 2 meters away 

from any interfering sources such as computer monitors or TV sets. 

2. 

Avoid placing the transmitters onto or in the immediate proximity of metal window 

frames. 

3. 

Using other electrical products such as headphones or speakers operating on the 

868MHz-signal frequency may prevent correct signal transmission or reception. 

Neighbors using electrical devices operating on the 868MHz-signal frequency can also 

cause interference. 

 

Note:

 

 

When the 868MHz signal is received correctly, do not re-open the battery cover of either the 

transmitter or weather station, as the batteries may spring free from the contacts and force a 

false reset. Should this happen accidentally then reset all units (see “

Setting up

” above) 

otherwise transmission problems may occur. 

The transmission range is around 100 meters from the thermo-hygro transmitter to the 

weather station (in open space). However, this depends on the surrounding environment and 

interference levels. If no reception is possible despite the observation of these factors, all 

system units have to be reset (see “

Setting up

 

above). 

 

POSITIONING THE WEATHER STATION 

The weather station provides the option of table standing or wall mounting 
the unit. Before wall mounting, please check that the outdoor data can be 
received from the desired locations.  

 

To wall mount: 

1. 

Fix a screw (not supplied) into the desired wall, leaving the head 
extended out by about 5mm.  

2. 

Place the weather station onto the screw, using the hanging hole on 
the backside. Gently pull the weather station down to lock the screw 
into place. 

 

Foldout table stand: 

The foldout table stand leg is located on the backside. Pull the stand out 
from the bottom center edge of the weather station, below the battery 
compartment. Once the foldout table stand is extended, place the 
weather station in an appropriate location.

 

 
 
 
POSITIONING THE THERMO-HYGRO TRANSMITTER 

Mounting at a sheltered place. Avoid direct rain and sunshine.

  

 

The thermo-hygro transmitter can be placed onto any flat surface or wall 
mount using the bracket which doubles as a stand or wall mount base. 

 

 
 

 
 
 
 
 
 

 
 

To wall mount:  

1. 

Secure the bracket onto a desired wall using the screws and plastic anchors. 

2. 

Clip the transmitter onto the bracket.   

 

Note:

  

Before permanently fixing the thermo-hygro to the wall base, pace all units in the desired 

locations to check that the outdoor temperature and humidity readings are receivable. In 

event that the signal is not received, relocate the thermo-hygro transmitter or the weather 

station slightly as this may help the signal reception. 

 

CARE AND MAINTENANCE  

 

Extreme temperatures, vibration and shock should be avoided as these may cause 

damage to the unit and give inaccurate forecasts and readings. 

 

When cleaning the display and casings, use a soft damp cloth only. Do not use 

solvents or scouring agents as they may mark the LCD and casings. 

 

Do not submerge the unit in water. 

 

Immediately remove all low powered batteries to avoid leakage and damage. Replace 

only with new batteries of the recommended type. 

 

Do not make any repair attempts to the unit. Return them to their original point of 

purchase for repair by a qualified engineer. Opening and tampering with the unit may 

invalidate their guarantee. 

 

Do not expose the units to extreme and sudden temperature changes, this may lead to 

rapid changes in forecasts and readings and thereby reduce their accuracy. 

 

 

 

 

 

 

 

The declaration of Conformity can be found at: 

www.mobile-alerts.fr

 

 

 

 

SPECIFICATIONS 

Recommended operating temperature range 

:   5ºC to 40ºC

 

Temperature measuring range: 

Indoor 

-9.9ºC to +59.9ºC with 0.1ºC resolution  

 

 

(

“OF.L”

 displayed if outside this range) 

Outdoor 

-39.9ºC to +59.9ºC with 0.1ºC resolution  

 

 

(

“OF.L”

 displayed if outside this range, “---“ displayed if no transmitter signal) 

Humidity measuring range: 

Indoor humidity range   :  20% to 95% with 1% resolution  

 

    (Display “- -“ if temperature is OL.F; display “19%“ if < 20% and 

“96%” if > 95%) 

Outdoor humidity range  :   1% to 99% with 1% resolution (Display “- -“ if outside 

temperature is OF.L; display 1% if < 1% and 99% if > 99%) 

Data checking intervals:

 

Indoor temperature checking interval  :   every 2 minutes 
Outdoor temperature reception 

:   every 2 minutes 

Transmission to Gateway                    :   every 6 minutes  
Transmission range 

 

:    up to 100 meters (open space) 

Power consumption 

(alkaline batteries recommended): 

Weather station 

:   3 x AAA, IEC, LR3 1.5V 

Transmitter 

:   2 x AA, IEC, LR6, 1.5V 

Dimensions (L x W x H): 

Weather station     

 

170.8 x 28.3 x 127mm 

Transmitter  

   

 

38.2 x 21.2 x 128.3 mm  

  

 
 
 

LIABILITY DISCLAIMER: 

 

The electrical and electronic wastes contain hazardous substances. Disposal of 

electronic waste in wild country and/or in unauthorized grounds strongly damages the 

environment. 

 

Please contact your local and/or regional authorities to retrieve the addresses of legal 

dumping grounds with selective collection. 

 

All electronic instruments must from now on be recycled.  User shall take an active part 

in the reuse, recycling and recovery of the electrical and electronic waste. 

 

The unrestricted disposal of electronic waste may do harm on public health and the 

quality of environment. 

 

As stated on the gift box and labeled on the product, reading the “User manual” is 

highly recommended for the benefit of the user. This product must however not be 

thrown in general rubbish collection points. 

 

The manufacturer and supplier cannot accept any responsibility for any incorrect 

readings and any consequences that occur should an inaccurate reading take place. 

 

This product is designed for use in the home only as indication of the temperature. 

 

This product is not to be used for medical purposes or for public information. 

 

The specifications of this product may change without prior notice. 

 

This product is not a toy. Keep out of the reach of children.

 

 

No part of this manual may be reproduced without written authorization of the 

manufacturer.

 

 

 

 

 

PRECAUTIONS 

This main unit is intended to be used only indoors. 
Do not subject the unit to excessive force or shock. 
Do not expose the unit to extreme temperatures, direct sunlight, dust or humidity. 
Do not immerse in water. 
Avoid contact with any corrosive materials. 
Do not dispose this unit in a fire as it may explode. 
Do not open the inner back case or tamper with any components of this unit. 

 

BATTERY SAFETY WARNINGS 

Please read all instructions carefully before use. 
Use only alkaline batteries, not rechargeable batteries. 
Install batteries correctly by matching the polarities (+/-). 
Always replace a complete set of batteries. 
Never mix used and new batteries. 
Remove exhausted batteries immediately. 
Remove batteries when not in use. 
Do not recharge and do not dispose of batteries in fire as the batteries may explode. 
Ensure batteries are stored away from metal objects as contact may cause a short 
circuit. 
Avoid exposing batteries to extreme temperature or humidity or direct sunlight. 
Keep all batteries out of reach from children. They are a choking hazard. 

 

 

 

 

 

 

Please participate in the preservation of the environment. Return used batteries 
to an authorised depot. 

 

 

 

 

 

 

 
 
 
 

 

R&TTE Directive 2014/53/EU 

Summary of the Declaration of Conformity:  We hereby declare that this wireless transmission device 
does comply with the essential requirements of R&TTE Directive 2014/53/EU. 

  

 

TROUBLESHOOTING 

When no sensor readings are displayed in the app, check if the green LED on the gateway is 
permanently lit. If not, please check if: 
- The gateway is properly connected to the power plug, the router and is turned on. 
- Restart the station by removing the batteries for a minute and reinserting, to restart the 
device. 
- Your phone is connected to the internet. 
- The signal is weakened by thick walls and ceilings. Put the device in operation near the 
gateway and then locate a suitable location. 

More information and detailed instructions can be found in the app at “Info” or at 

www.mobile-alerts.fr 

Air pressure trend over the 
last 12 hours 

Outdoor humidity 
in RH%

 

Outdoor 
reception 
icon

 

Outdoor 

temperature 

in 

C

Recorded 
time of the 
outdoor 
MIN/MAX 
records 

Recorded 
date of the 
outdoor 
MIN/MAX 
records 

MAX outdoor 
temperature 

MAX icon (outdoor 
temperature) 

Отзывы: