![MOBILE-ALERTS MA 10061 Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/mobile-alerts/ma-10061/ma-10061_instruction-manual_1815375003.webp)
Installation
Download the App
Download the MOBILE-ALERTS app from "Apple App Store" or "Google Play".
Connect the Gateway
Connect the gateway to power supply using the supplied AC adapter. Connect included LAN cable with the
gateway and your router. After about 10 seconds, the Gateway is in operation. The LED will turn static green.
If no DHCP server is available in your network, you can configure the gateway in the app under the point
“Settings” manually.
Important: The Gateway should always be put into operation before starting the sensors!
Installation of Sensors
Setting up the thermo / hygro transmitter
•
Pull off the protection cap and open the battery compartment of the temperature sensor and put in 2x C
batteries with the correct polarity.
•
Close the lid of the battery compartment and replace the protection cap.
Setting up the rain gauge
•
Open the cover of the rain gauge by counter-rotating the base to the lid and then remove the cover.
•
Remove the transport securing of the seesaw. The seesaw should be freely moveable forward and backward
now.
•
Remove the lid of the battery compartment on the bottom of the sensor by loosening the screw.
•
Insert 2x AA batteries with correct polarity and close the lid of the battery compartment by tightening the screw.
Setting up the wind sensor
•
Remove the protective film from the solar panel
•
Press the reset button on the bottom of the sensor using the supplied plastic rod
Add sensors
•
Open the app, dashboard is displayed.
•
The sensors with the prefix "Sample" are only for demonstration purposes and can be deleted.
•
Tap "Add new sensor" and scan the QR code on the back or bottom of the temperature sensor.
•
Then set a name for the sensor. To set a name, select the transmitter and then tap on the left area of the pencil
icon in the upper right.
•
Confirm the name by pressing the Enter button, then tap Back.
Read measurements
•
Now you can read the measurements on your mobile phone.
•
For more information on using the app and sensor-specific settings can be found in the app under "Info".
Mounting Sensors
Below we will give you instructions for placement and mounting of the measuring units:
•
Ensure that all of the sensor data can be received by the gateway at the intended
mounting locations. Trees, metal surfaces, walls and electronic devices can interfere with transmission.
•
Please check whether the stations are accessible for cleaning and maintenance easy too.
•
The sensors should be cleaned regularly, as dirt residues can affect the measurements.