Mobi Technologies HEALTH CHECK Скачать руководство пользователя страница 2

Health Check 

Press buttons ‘MEM/SET’ and ‘MODE’ together for 2 seconds to enter the 
countdown. Use the ‘MODE’ button to toggle between 15 minutes, 30 

minutes or 45 minutes or OFF.

Press the ‘MEM/SET’ button when the desired time is on screen to start 

counting down. When the countdown is active and running in the 

background the “ ” sign will flash on screen.

When the countdown begins, the user can press ‘MEM/SET’ and ‘MODE’ 

button together for 2 seconds to display the remaining time, then press 

‘SCAN’ button to return to waiting mode or press ‘MEM/SET’ button to cancel 

the countdown.

When the countdown is zero. Health check “ ” symbol will display on LCD and 
the unit will ‘BEEP’ to remind the user. To stop the notification’s and return to 

the home menu press any button.

Memory Function

This unit can recall up to 9 prior measurements stored in memory.

Turn on thermometer, press the ‘MEM’ button once, then press it again to 

show the last measurement.  

The symbols for ‘EAR’ or ‘FOREHEAD’ will appear with each measurement 
stored in memory to indicate whether a person’s forehead or ear 

temperature was taken.

Each press of the same button recalls a previous measurement. 

Troubleshooting

Problem

Checklist

Countermeasure

No response/automatic 
reset when pulling out 
plastic insulator tab.

Batteries are low or dead
Batteries installed in 
wrong polarity? 
Poor battery contact?

Change to new 
batteries
Remove batteries and 
reinsert batteries 
correctly

Measured temperature 
is lower than 
89.6°F/32.0°F or higher 
than 109°F/42.9°C

Follow steps in user 
manual for correct 
measurements. 
Check the device is in 
the correct operating 
mode.

These Error messages 
indicate a problem with 
the hardware.

Contact Mobi 
Technologies, Inc. via 
contacting information 
at the end of this 
manual.

Operating Temperature is 
out of the range

Use the thermometer in 
the range of operating 
conditions

The sensor temperature 
has not been stabilized

Wait 10 seconds and 
take a measurement 
again. 

The measurement is 
not accurate or there is 
doubt of measurement 
results.

Check to see if the 
infrared sensor is clean or 
not.

Clean the infrared 
sensor with cotton swab 
according to the user 
manual. 

Determine whether your 
measuring method is 
correct or not. 

Please review the user 
manual and ensure you 
are operating the 
thermometer correctly.

Assess whether you have 
allowed the thermometer 
and the patient to 
become stabilized in the 
room for 30 minutes.

Please ensure the 
thermometer and 
patient remain in the 
location for at least 30 
minutes before 
recording a 
temperature.

Are you using the 
thermometer indoors or 
outdoors.

Always do the 
measurements indoors.

Determine if you might 
have held the 
thermometer in your 
hand too long which may 
affect its accuracy.

Place the thermometer 
in the room where the 
measurement is due to 
be taken, let it stabilize 
for 30 minutes before 
use.  

Check to see if the Low 
Battery icon is showing on 
the LCD screen.

Immediately replace the 
batteries with new ones.

Product Safety & Warnings

WARNING:

WARNING:

WARNING:

WARNING:

WARNING:

WARNING:

This product was designed to measure human body 
temperature on the forehead, do not use this for any other 
purpose.
Do not use this thermometer if it has been malfunctioning or it 
has been damaged.
This product is not waterproof. Do not use this product under 
any wet conditions and do not immerse in any liquid or water.
This product should not be left alone with children or pets with 
not in use by an adult.
Do not store the thermometer in extreme temperatures below 
(-4°F / -20°C) or over (131°F/ 55°C).
Do not use the product in a wet ear canal after swimming or 
bathing. It is possible to damage the ear canal.

Equipment Symbols

Warning

Compliance with WEEE Standard

Non-Sterile 
Packaging

DO NO THROW AWAY intended 
for multiple use

Refer to 
Operating 
Instructions

Operating atmospheric pressure

Operating 
Temperature

Serial number

Operating 
Humidity

Recyclable

Manufacturer

This device compiles with Part 15 
of FCC (federal communications 
commission) rules.

IP22: The first number 2: Protected against solid foreign objects to 

12.5mm Φ and greater. The second number: Protected against 

vertically falling water drops, when enclosure titled up to 15°.

Limited Product Warranty 

MOBI® warrants its products to be free from defects in material and 
workmanship for period of (1 Year) from the date of purchase. Should the 
product prove to be defective at any time during the warranty period, we would 
either replace or repair the product at our option without charge. After the 
warranty period, a service charge will apply for replacement of parts and labor 
costs. To obtain warranty service, you must return the product complete with its 
original parts & accessories along with a copy of the original purchase, gift or 
registry receipt to us. This warranty does not cover damage caused by any 
tampering, accident, misuse, abuse, improper maintenance, unauthorized 
modification, or connection to an improper power supply. There will be a charge 
for repair caused for such damage. This warranty excludes all incidental or 
consequential damages and any liability other than stated above.

Questions? 

Please visit

www.getmobi.com

Email

[email protected]

Note: For Detailed Instructional Manual please follow this link: 

http://www.getmobi.com/users-manuals

© 2021 MOBI Technologies, Inc.

All Rights Reserved

Отзывы: