© MOBATIME
35/40
BE-801259.05-HN 60&61master clock
Option / Accessories
DCF 77 radio
F
unkempfänger
AD 650
✓
-
✓
-
✓
-
✓
DCF 77 radio
receiver
back-up battery pack
Lead battery 0,8 Ah, 12 V
D
ime
nsi
on
s
[mm]
/
W
ei
gh
t [
kg
]
106 (6M) x 92 x 40 / 0.5
BP 60/50 12V
striking module
53 (3M) x 90 x 62 / 0,.2
(HN 60m / 61m only)
-
53 (3M) x 90 x 62 / 0.2
HN..SSR2
for indoor wall mounting
✓
HN 6x IP 40 case
for outdoor wall mounting
✓
12.2 Power supply, parameters and options
Property
Values
3)
power source
1)
230 VAC +/- 10 %
24 VDC +/- 5 %
13 VDC +/- 10 %
power supply terminal
L N PE
VDC
ACCU
voltage at the ACCU terminal
14 VDC
14 VDC
-
4)
max possible current
consumption from ACCU
terminal
200 mA
200 mA
-
voltage at the VDC terminal
24 VDC
-
24 VDC
4)
max possible current
consumption from VDC terminal
200 mA
-
200 mA
2)
impulse line voltage
12/24 V
12/24 V
12/24 V
active operaration reserve
Pb accumulator
✓
-
-
5)
fitted jumper Accu connect
-
-
✓
voltage type
AC voltage,
sine 50-60 Hz
DC voltage,
stabilized and smoothed
Note:
1) according to the type of clock - see the table in chapter 12.1 Technical data
2) default value - 24 V; 12 V can be selected in the Service menu
3) if the tolerance of the supplied supply voltage is not observed, or if another type of voltage is
used, the correct operation of the main clock cannot be guaranteed
4) the total power supplied to the connected equipment consists of consumption of the
secondary line, consumption at the ACCU and VDC terminals; the maximum values of the
specified currents cannot be supplied to the load at the same time