© MOBATIME
21 / 52
801317.00
4.2.3
Submenu for network services configuration
Choose the value
2
or
3
in the item
P19
(network work mode selection) in the
clock menu, then enter the submenu by pushing the
SET
for configuring the
network services (Multicast support in unicast work mode, SNMP service, Telnet
service). The item to be set is blinking.
The display shows the following:
Set value
1
for enabling the multicast
support in the unicast work mode or
value
0
for disabling it.
Switch to the next parameter
– SNMP communication support by pushing the
>>
.
The display shows the
Sn: 1
. Set value
1
for enabling the SNMP support or value
0
for disabling it.
Switch to the next parameter
– Telnet support by pushing the
>>
. The display
shows the
tn: 1
. Set value
1
for enabling the telnet support or value
0
for
disabling it.
By pushing
OK
, the entered values are stored and the clock returns to the menu
item
P19
. By pushing
ESC
, the clock returns to
P19
without saving.
4.2.4 Manual setting of the IP address of the clock
Choose the item
P20
in the
main
menu and push the
SET
button to enter the
submenu for setting the IP address. The item to be set is blinking.
The display shows the following:
Enter four octets of the IP address step
by step. Switch to another octet by
pushing the
<<
and
>>
buttons. Octets
are marked by letters
A
,
b
,
C
and
d
.
By pushing
OK,
the entered values are stored and the clock returns to the menu
item
P20.
By pushing
ESC
the clock returns to
P20
without storing.
4.2.5 Manual setting of the subnet mask
Choose the item
P21
in the
main
menu and push the
SET
button to enter the
submenu for setting the subnet mask. The item to be set is blinking.
The display shows the following:
Enter the four octets of the subnet mask
step by step. Switch to another octet by
pushing the
<<
and
>>
buttons. Octets
are marked by letters
A
,
b
,
C
a
d
.
By pushing
OK,
the entered values are stored and the clock returns to the menu
item
P21.
By pushing
ESC
, the clock returns to
P21
without saving.
4.2.6 Manual setting of default gateway IP address
Choose the item
P22
in the
main
menu and push the
SET
button to enter the
submenu for setting the default gateway IP address, the item to be set is blinking.
Содержание ECO-M-DK
Страница 1: ... MOBATIME BE 801317 00 INSTRUCTION MANUAL State of the art technology digital clock ECO M DK ...
Страница 8: ... MOBATIME 8 52 801317 00 2 3 Assembly diagram Single sided clock Double sided clock ...
Страница 9: ... MOBATIME 9 52 801317 00 2 4 Mechanical drawing Single sided clock Double sided clock ...
Страница 11: ... MOBATIME 11 52 801317 00 2 6 Control PCB ...
Страница 50: ... MOBATIME 50 52 801317 00 ...
Страница 51: ... MOBATIME 51 52 801317 00 ...