RS 485 Clock line
Monitored clock line for 31 slave clocks
(only available with the DTS 4801)
1. Select mode: Line switched off, RS485 line, serial telegrams
2. RS-485 mode: Off, monitored, 12 o’clock position
3. Select time zone (see chapter “6.5.28 Time zone selection“)
4. Switch function: 0=off, 1-64 = channel number of the switch functionality
5. Select and configure the slave clocks (menu RS 485 clock line)
6. Display error list (history) of the clock line (error list of the RS 485 slave clock line,
see the following pages)
Important:
To set the parameters, the line type has to be selected first!
The RS485 line communicates with the following communication parameters via the
RS485 interface:
9600 bauds, 7 data bits, even parity, 1 stop bit, no flow control
The MOBA-RS485 PROTOCOL is used for the monitored clocks.
The broadcast function can be configured with the serial telgramm MC482STD.TEL.