Mounting
29
Fig.8-2: Mounting display
•
Screw on the RAM-Mount adapter with three M5 screws according to illustration
8-2 (recommended screws: hexagon, VA steel).
•
Also using three M5 screws, mount the second RAM-Mount adapter together
with the mounting arm onto the fixing holes provided on the housing rear side.
•
Then connect the display and the RAM-Mount adapter (see Fig. 8-2).
Alternatively, mounting can also be done using a RAM-Mount holder with
magnetic attachments.
8.1.2 Mounting of ultrasonic sensors (MOBA Sonic-Ski Plus)
In order to carry out correct layer thickness measurements, two sensors must be
mounted on each side of the paver. The sensors themselves must be attached
laterally to the direction of travel.
NOTE!
Important note regarding proper function!
The following must be observed for the MOBA Pave-TM system to
operate as intended:
•
There must be no material below the front sensors. If
necessary, install a protective plate or similar.
•
The supply lines to the sensors must not be squeezed or torn
off by moving parts.