7
Be careful to connect the heater to a supply line protected by 16 A fuses not quick-
acting type.
• The heaters should always be installed horizontally only using the mounting brackets
provided. This ensures correct positioning and adequate clearance.
• A minimum air gap of 30 cm should always be allowed between the top of the heater and
a ceiling or roof. The appliance should be 30 cm far from the walls. In case of wall mount-
ing, leave a minimum gap of 8 cm between the wall and the edge of the heater (fig. 1).
• A safety distance of not less than 100 cm should always be left in front of the SHARKLITE
heaters or too near.
• This unit should be mounted at a minimum of 180 cm above ground level (fig. 1). If
installed in a toilet, the height should be 225 cm in zone 1 and zone 2; in zone 3 the mini-
mum above ground level is 180 cm, according with the rules of each Country.
• Be sure that the heater is not facing the ceiling or inflammable substances.
• The appliance must not be located neither directly below, nor in front of a socket-outlet.
• The heater must be installed so as to prevent that the switches can be touched from
those who are in the shower.
• Ensure that there is no possibility of inflammable material, combustible material or cur-
tains coming into contact with the heater, or lie near the heater.
• Heaters should not be installed in areas where hazardous vapours may be present. De-
fined in BS5345.
• The heaters are fitted with safety guards. These are intended only to stop large objects
from hitting the emitters. On no account should the heater be operated with the guard
removed.
• For consumer use the heaters are fitted with high temperaure rubber flexible cable (H05
RN-F) conforming to BS6500.
• The models for professional use, that are marked with a “P” in the code, do not have
the power cord. For professional installation, cabling of the same specification should be
selected.
• The product is in class I and IP55, which is the protection rate for the units to be used
when outdoor. For keeping the protection rate of the appliance, the connection of the
appliance with the power supply must be done by means of a minimum IP55 system, as
per the standards HD 384 CENELEC for Europe, or international IEC 60346-7-708 1988,
and the standard AS/NZS 3000 (Australian wiring rules).
• Means for disconnection must be incorporated in the fixed wiring in accordance with the
wiring rules.
• Avoid to touch the metal parts.
3. LOCATION
The Sharklite range of heaters is deliberately designed to be very flexible in the choice of
position. There are the following basic options:
Wall mounting version — fig. 2
. Before drill the holes for the dowels, be sure that the wall
is solid and that you are far from water tubes or electrical wires. Apply the aluminium bracket
on the wall and mark the holes position with a pen or a screwdriver. For fixing the appliance
at the wall, drill two holes with a 5 mm diameter bit and fix the aluminum bracket with the
dowels and screws that you find in the box. Then fix the appliance to the wall bracket using
the 2 screws with dowels. Check that the arrow on the label is turned up.
Содержание SHARKLITE 712
Страница 26: ...26 ...
Страница 27: ...27 ...
Страница 28: ...28 Fig 1 Fig 2 SWITCH ...
Страница 29: ...29 Fig 3 Cod 705 Fig 4 Cod 702 ...
Страница 30: ...30 ...
Страница 31: ...31 ...
Страница 32: ...002961 09 2013 ...