3. ThingSpeak
3.1. General
The ThingSpeak data interface is integrated into the MATLAB mathematics soft-
ware, which offers many possibilities for further processing.
Information about the license models can be found at
.
3.2. Setting up ThingSpeak
After creating a ThingSpeak user account, log in and create a channel for the
VM40C (Figures 18 and 19).
A ThingSpeak channel consists of a maximum of eight data fields, of which the
VM40C uses six in the following manner:
Field 1: Current status; OK/Warning/Alarm (0/1/2).
Field 2: Measured value X in mm/s or m/s² (for SN 640312a the vector sum)
Field 3: Measured value Y in mm/s or m/s² (for SN 640312a zero)
Field 4: Measured value Z in mm/s or m/s² (for SN 640312a zero)
Field 5: Main frequency in Hz
Field 6: Battery charge in percent
10
Figure 19: Entered channel
Figure 18: ThingSpeak channel menu
Содержание VM40C
Страница 4: ......
Страница 17: ...13 Figure 25 Channel settings ...
Страница 19: ...15 Figure 26 Example of a measuring channel view in ThingSpeak ...