• Connect the pre-wired 6-way hub to the secondary side of the driver ensuring that correct
polarity is observed: Positive – (red); Negative – (black)
• Connect the driver to the mains supply ensuring that correct polarity is observed: L – Live
(brown), N – Neutral (blue)
• Switch on and check for correct operation
Surface Mounting
• Provide power to the required point of installation
• Using the mounting bracket as a template, mark the location for, and drill the fixing holes
ensuring not to infringe with any gas/water pipes or electrical cables
• Fix the base to a suitable solid surface using the screws provided. Please ensure that the
lamp cable is routed through the slot in the backplate (see Fig. 4)
• Connect the lamp to the 6-way hub (see Fig. 5)
Fig. 4
•
Connect the lamp to the 6-way hub (see Fig. 5)
Fig. 5
Note
–
Before adding or removing lamps from the 6-way hub, please ensure that the power to the kit is
switched off. Please note that if more lamps are needed, up to a maximum of 6, a connector should be removed
from the hub and replaced by a lamp. Connectors must be inserted in any unused hub terminals for the kit to
work.
The minimum number of lamps per driver is 2, if fewer are used this will cause irreparable damage
to the lamp.
•
Connect the pre-wired 6-way hub to the secondary side of the driver ensuring that correct polarity is
observed: Positive
–
(red); Negative
–
(black)
•
Connect the driver to the mains supply ensuring that correct polarity is observed: L
–
Live (brown), N
–
Neutral (blue)
•
Switch on and check for correct operation
Fig. 4