background image

INSTALLATION & MAINTENANCE MANUAL

UNDKIT3WWW / UNDKIT3WCW  

UNDKIT3BCWW / UNDKIT3BCCW

Содержание UNDKIT3WWW

Страница 1: ...INSTALLATION MAINTENANCE MANUAL UNDKIT3WWW UNDKIT3WCW UNDKIT3BCWW UNDKIT3BCCW ...

Страница 2: ...rent Building Regulations If in any doubt consult a qualified electrician Please isolate mains prior to installation or maintenance Check the total load on the circuit including when this luminaire is fitted does not exceed the rating of the circuit cable fuse or circuit breaker Please note the IP Ingress Protection rating of this luminaire when deciding the location for installation This product ...

Страница 3: ...e Fig 1 ensuring not to infringe with any joists gas water pipes or electrical cables Remove the backplate and fit the lamp into the cut out see Fig 2 Fig 1 uminaire is being used in conjunction with an external PIR or sensor please of the sensors that they are compatible with LED luminaires tallation de power to the required point of installation suitable hole in the mounting surface as per the c...

Страница 4: ...ive black river to the mains supply ensuring that correct polarity is observed L Live brown check for correct operation 6 way hub see Fig 3 Fig 2 Fig 3 Connect the lamp to the 6 way hub see Fig 3 Note Before adding or removing lamps from the 6 way hub please ensure that the power to the kit is switched off Please note that if more lamps are needed up to a maximum of 6 a connector should be removed...

Страница 5: ...d check for correct operation Surface Mounting Provide power to the required point of installation Using the mounting bracket as a template mark the location for and drill the fixing holes ensuring not to infringe with any gas water pipes or electrical cables Fix the base to a suitable solid surface using the screws provided Please ensure that the lamp cable is routed through the slot in the backp...

Страница 6: ...f Please note that if more lamps are needed up to a maximum of 6 a connector should be removed from the hub and replaced by a lamp Connectors must be inserted in any unused hub terminals for the kit to work The minimum number of lamps per driver is 2 if fewer are used this will cause irreparable damage to the lamp Connect the prewired 6 way hub to the secondary side of the driver ensuring correct ...

Страница 7: ...r The LED lamps fitted in this product are non replaceable The product should be recycled in the correct manner when it reaches the end of its life Check local authorities for where facilities exist Clean with a soft dry cloth only do not use aggressive cleaning products or solvents which may damage the product This luminaire is dimmable with a trailing edge dimmer only PART CODE DESCRIPTION UNDK3...

Страница 8: ...ing Regulations BS7671 improper use or removal of the batch code will invalidate the warranty If this product should fail within its warranty period it should be returned to the place of purchase for a free of charge replacement ML Accessories does not accept responsibility for any installation costs associated with the replacement product Your statutory rights are not affected ML Accessories rese...

Отзывы: