• Feed the cables through the compression glands on the bottom of the sensor
• Connect the sensor to the mains supply ensuring the correct polarity is observed (see Fig. 1): L - Live 

(brown), N - Neutral (blue)

• Connect the load to the sensor ensuring the correct polarity is observed (see Fig. 1): L - Live (brown),  

N - Neutral (blue)

INSTALLATION & MAINTENANCE MANUAL 

These instructions should be read carefully and retained after installation by the end user for future reference 

and maintenance. 

These instructions should be used to aid the installation of the following product: 

OSPCKIT 
SAFETY 

 

This product must be installed in accordance with the latest edition of the IEE Wiring Regulations 

(BS7671) and current Building Regulations. If in any doubt, consult a qualified electrician 

 

Please isolate mains prior to installation or maintenance 

 

Check the total load on the circuit (including when this product is fitted) does not exceed the rating of 

the circuit cable, fuse, or circuit breaker 

 

Please note the IP (Ingress Protection) rating of this product when deciding the location for installation 

 

Do not overload this accessory or subject it to conditions outside its rating 

 

This product is Class II double insulated  

 

This product is IP66 rated 

INSTALLATION 
 

 

Provide power to the required point of installation (refer to BS7671 for correct cabling methods). 

Suitable IP rated junction boxes should be used where required 

 

The power source connections should be local and accessible via a suitable IP rated enclosure 

 

Round cable should be used for the mains supply. The use of flat cable will cause water ingress to the 

fitting 

 

Using the mounting bracket as a template, mark the location for, and drill the fixing holes ensuring not 

to infringe with any gas/water pipes or electrical cables  

 

Fix the bracket to a suitable solid surface using the screws provided 

 

Unscrew the three screws on the bottom of the sensor and remove the plastic cover 

 

Feed the cables through the compression glands on the bottom of the sensor 

 

Connect the sensor to the mains supply ensuring the correct polarity is observed (see Fig. 1): L - Live 

(brown), N - Neutral (blue) 

 

Connect the load to the sensor ensuring the correct polarity is observed (see Fig. 1): L - Live (brown), 

N - Neutral (blue) 

 

 

 

 

 

 

 

 

Fig. 1 

 

 

 

 

 

 

 

Adjust the lux level 

 

Reattach the plastic cover and tighten the compression glands 

 

Slide the sensor onto the mounting bracket 

 

Switch on and check for correct operation 

 
 
 

Fig. 1

• Adjust the lux level
• Reattach the plastic cover and tighten the compression glands
• Slide the sensor onto the mounting bracket
• Switch on and check for correct operation

Содержание OSPCKIT

Страница 1: ...INSTALLATION MAINTENANCE MANUAL OSPCKIT ...

Страница 2: ...duct when deciding the location for installation Do not overload this accessory or subject it to conditions outside its rating This product is Class II double insulated This product is IP66 rated SAFETY INSTALLATION Provide power to the required point of installation refer to BS7671 for correct cabling methods Suitable IP rated junction boxes should be used where required The power source connecti...

Страница 3: ...ver Feed the cables through the compression glands on the bottom of the sensor Connect the sensor to the mains supply ensuring the correct polarity is observed see Fig 1 L Live brown N Neutral blue Connect the load to the sensor ensuring the correct polarity is observed see Fig 1 L Live brown N Neutral blue Fig 1 Adjust the lux level Reattach the plastic cover and tighten the compression glands Sl...

Страница 4: ... the product s product should be recycled in the correct manner when it reaches the end of its life Check local authorities where facilities exist ARRANTY s product has a warranty of 1 year from the date of purchase Failure to install this product in accordance h the current edition of the IEE Wiring Regulations BS7671 improper use or removal of the batch code will Fig 2 WARNING GENERAL This produ...

Страница 5: ... batch code will invalidate the warranty If this product should fail within its warranty period it should be returned to the place of purchase for a free of charge replacement ML Accessories does not accept responsibility for any installation costs associated with the replacement product Your statutory rights are not affected ML Accessories reserve the right to alter product specification without ...

Страница 6: ...AVJUL21_V1 ML Accessories Limited LU5 4LT www mlaccessories co uk 116 INTERNATIONAL CONTACT DETAILS INTERNAT CONTACT D ...

Отзывы: