2
These instructions should be read carefully and retained after installation by the end user for
future reference and maintenance.
These instructions should be used to aid installation of the following products:
For all MLA’s standard 12V / 24V DC LED Flex, which includes:
LEDFS12WW / LEDFS12DL / LEDFH24WW / LEDFH24DL / LEDFN12WW / LEDFN12DL / LEDFN12B
LEDFN12G / LEDFN12R / LEDFN212WW / LEDFN212DL / LEDFN24WW / LEDFN24DL / LEDFN12CW
GENERAL INSTRUCTIONS
SAFETY
INSTALLATION
• Installation of this product should only be carried out by a qualified electrician or competent person to the
current Building and IEE Wiring Regulations (BS7671)
• Please isolate mains prior to installation/maintenance
• Check the total load on the circuit (including when this product is fitted) does not exceed the rating of the
circuit cable, fuse or circuit breaker
• Please note the IP (Ingress Protection) rating of this product when deciding the location for installation
• This product is Class III
• This product is IP20 rated
• This product is dimmable when used with LEDFR1 or LEDFR7 dimming controllers
Note
- The use of an amplifier is recommended for installations above 10 metres as voltage drop may occur
• Provide power to the point of installation
• Decide on the desired layout of the LED Flex taking into consideration the following:
a) The cables are long enough to connect to the driver
b) The LED Flex is not going to be installed in a position where it is at risk of being cut, trapped or damaged
c) The total maximum length does not exceed the max power rating of the LED driver (see website for more
details)
• When cutting the LED Flex, ensure it is only cut along the line indicated between the copper connections,
approximately every 50mm (for 12V) and 100mm (for 24V) along the strips’ length (see Fig. 1)
LED FLEX SINGLE COLOUR
These instructions should be read carefully and retained after installation by the end user for future reference and
maintenance.
These instructions should be used to aid installation of the following products:
LEDFS12WW / LEDFS12DL / LEDFH24WW / LEDFH24DL / LEDFN12WW / LEDFN12DL / LEDFN12B / LEDFN12G / LEDFN12R
/ LEDFN212WW / LEDFN212DL / LEDFN24WW / LEDFN24DL
SAFETY
•
Installation of this product should only be carried out by a qualified electrician or competent person to the
current Building and IEE Wiring Regulations (BS7671)
•
Please isolate mains prior to installation/maintenance
•
Check the total load on the circuit (including when this luminaire is fitted) does not exceed the rating of the
circuit cable, fuse or circuit breaker
•
Please note the IP (Ingress of Protection) rating of this product when deciding the location for installation
•
This product is Class III
•
This product is IP20 rated
•
This product is dimmable when used with LEDFR1 or LEDFR6 dimming controllers
INSTALLATION
•
Provide power to the point of installation
•
Decide on the desired layout of the LED Flex, taking into consideration the following:
a)
The cables are long enough to connect to the driver
b)
The LED Flex is not going to be installed in a position where it is at risk of being cut, trapped or
damaged
c)
The total maximum length does not exceed the max power rating of the LED driver (see website for
more details)
•
When cutting the LED Flex, ensure it is only cut between the copper connections, approximately every 50mm
along the strips’ length. It is important to only cut along the line indicated between the copper connections (see
Fig 1)
Fig 1
•
The LED Flex is provided with self-adhesive backing, ensure the surface application is clean and dust free before
installation
•
Ensuring correct polarity is observed, connect the 230V mains supply to the primary side of the 12/24V constant
voltage driver, Live (brown), Neutral (blue)
•
Terminate the 12V or 24V LED Flex to the secondary side of the driver ensuring correct polarity is observed (+
Red) (- Black) (see Fig 2)